3
T
ransporT
:
Lifting equipment should always be used to move the machine. Allowance should be made for the fact that
the machine is ‘top-heavy’.
The machine must not be pulled or lifted by the bowl lift handle.
When the machine is moved, it should be in a vertical position at all times.
i
nsTallaTion
and
fixinG
:
The ambient temperature around the machine must not exceed 45
o
C.
If the mixer is placed on a table, it must be bolted on to the table. Use 4 M8 bolts with a length of 130 mm + the thickness
of the table top,
see drawing page 12
If the mixer is placed on a bench stand, it can be placed direct on the floor. Foundation bolts in the floor are recommended.
Intermediate pieces can be inserted under the mixer’s feet, if the floor is not completely even.
Electrical connection:
Users can connect the mixer to the power supply themselves; refer to the section on
Electrical connection
which must be
followed.
For the benefit of service staff, it should be clear to see when the mains plug to the mixer has been removed from the
socket in the wall.
Before the machine is connected to the mains, check that the voltage and frequency printed on the name
plate are correct for the installation location. The name plate is placed at the top of the back of the mixer
There is a risk of injury if the machine is not earthed.
It must be ensured that the cable used to connect the machine to the mains meets the standard for the country
in which the machine is installed. See also
Example of electrical connections.
The mixer must be earthed. Failure to do so may cause injury
. If there is no earth connection, the EMC
filter will not work, with the risk of damage to the frequency converter.
When the machine is connected,
phase + n earth
or
phase + phase + earth
should be used. In
both cases, it is important to ensure that the voltage between the two live pins matches the name plate.
(See
examples below)
The machine must only be connected to an earthed mains supply.
A plug with two pins plus earth should be used. Alternatively, two wires plus earth from a three-phase supply
may be used.
The machine should be protected by a differential switch.
The machine is protected by a 5A fuse. The fuse is built into the socket on the back of the machine. To this
comes a 10A fuse which is mounted in the frequency converter, see
“Service instructions” page 12.
Voltage at the installation: 50/60 Hz
The machine sign
Power:
Phases x voltage
With
neutral
Earth
Voltage
Phases
Use
neutral
Use
earth
Remarks
1 x 220-240V
Neutral
yes
230V
1
yes
yes
Please note that the mixer is able to run without
any connection to earth, but this causes a re-
duced functionality of the EMC-filter due to lack
of leakage to earth.
Of functional and safety reasons, the
machine should be connected to earth!.
2 or 3 x 220-240V
-
yes
230V
2
-
yes
2 or 3 x 380-415V
Neutral
yes
230V
1
yes
yes
2 or 3 x 380-480V
-
yes
380-480V
2
-
yes
2 or 3 x 110-220V
Neutral
yes
100-110V
1
yes
yes
1 x 100-120V
Neutral
yes
100-110V
1
yes
yes
3 x 100-120V
-
yes
100-110V
2
-
yes
e
xamples
of
elecTrical
connecTions
: