Summary of Contents for RV 10 VL-2

Page 1: ...VL 2 Varimixer A S Kirkebjerg Søpark 6 DK 2605 Brøndby Denmark P 45 4344 2288 E info varimixer com www varimixer com Operating Instructions EN Ordrenummer 00242 Translation of the original user manual jan 2019 ...

Page 2: ...ns thoroughly particularly the section on user safety The manufacturer may update the product manual without updating this copy of the manual The manufacturer will not be liable for faults caused by Careless improper or incorrect use of the mixer Non standard use not for the purposes described in the manual Incorrect installation Incorrect power supply to the machine Failure to comply with mainten...

Page 3: ...country in which the machine is installed See also Example of electrical connections The mixer must be earthed Failure to do so may cause injury If there is no earth connection the EMC filter will not work with the risk of damage to the frequency converter When the machine is connected phase neutral earth or phase phase earth should be used In both cases it is important to ensure that the voltage ...

Page 4: ...accessories produced or recommended by Varimixer A S should be attached Max capacity of the machine AR absorption ratio AR liquid as of dry matter Local variations in the quality of the raw materials may affect water absorption volume baking characteristics etc and hence capacity Example Abasic recipe contains 1 kg of solids and 0 5 kg of liquid This gives AR 0 5 kg x 100 50 1 kg If for instance i...

Page 5: ...hen lifted the bowl should be fixed underneath the bowl fitting The bowl must be pushed all the way into the bowl arms Holder for scraper The one piece safety guard is made of trans parent plastic The guard is easy to remove and clean The guard can be machine washed at up to 60o and can withstand up to 90o for short periods The guard is made of a special impact re sistant material which can withst...

Page 6: ...mended uses of tool The whip should not be struck against hard objects such as the edge of the bowl This will shorten the life of the tool because of increasing deformation To make mashed potato use the beater and then the standard whip Cleaning The machine may only be cleaned by trained staff over 14 years of age The machine should be cleaned daily after use It should be wiped with a soft brush a...

Page 7: ... no light in the display If the red diode at is flashing the mixer has stopped because the safety circuit has been interrupted either because the bowl arms have been lowered or the safety guard has been removed The mixer is running and a speed has been chosen four diodes on the speed indicator are alight The speed can be changed by pushing one of the buttons for the four fixed speeds or or The mix...

Page 8: ...n in minutes and seconds in the timer field between and The maximum operating time is 60 minutes Inspection of the ingredients during operation If it is wished to stop the mixer without reducing operation time and speed push The mixer will reduce speed and then stop the operation time will also stop It is now possible to lower the bowl to check the ingredients Raise the bowl and push and the mixer...

Page 9: ...rt the mixer push and the program will be resumed Change of fixed speeds For the fields and it is possible to change the speed for future mixing jobs Push or to adjust the speed up or down If required to store the adjusted speed push or until two beeps are heard and the diodes of the speed indicator are flash ing The adjusted speed has now been stored in the memory To return to the factory setting...

Page 10: ...possible the product may be decomposed into smaller pieces or diluted before the mixer is restarted Finish the work in a lower speed Errors that do not cause an error code in the display The mixer does not start when is pushed but the timer is counting as normal There is no error code in the display Solution The frequency converter is defective and must be exchanged See Service Instructions page 1...

Page 11: ...ivate test program no 3 The motor starts and runs for approx 20 seconds After the 20 seconds a text is shown in the display this text will vary and can only be used for testing the function Test program 4 Test of micro switches in safety circuit Press to activate test program no 4 OBS It is important that the order is kept The cipher 1 is shown in the display until the safety guard is removed Remo...

Page 12: ...epair or adjustment the power must be switched off by dismantling the connection cable from the power supply Service instructions The mixer is to be bolted on to the table with 4 pcs M8 bolts The length of the bolts must be 130 mm the thickness of the table top Screws to be tightened with a torque 10A 8 8 Nm 13B 18 Nm 13C 9 Nm 13D 9 Nm ...

Page 13: ... screws are tightened 6C The motor pulley can be taken off by removing the locking ring 6E and then using a pulling off device 6D Take off the planetary head pulley in the following way a Take off the rear part 1 the lid of the mixer 2 and the Poly V belt 6 b Screw the pointed screws 6F out of the pulley The pulley can now be lifted off the clamping ring c To be able to loosen the clamping ring fr...

Page 14: ... Remove the screws 10A and lift out the planetary head d To mount the planetary head again follow the above instructions in reverse order note the torques declared for tightening screws 11 5A fuse can be exchanged by pulling out the small drawer 11A at the top of the cable plug 11B If the fuse is burned it can be ex changed by the reserve fuse 11C cable plug 11B Screws to be tightened with a torqu...

Page 15: ... from the female connector g The bracket with the micro switc is removed by loosen the screws 13D e Follow the instructions in reverse order note the torques declared for tightening screws 12 Exchange the switch for bowl lift in the following way a Take off the cover plate 8A on the back of the mixer b Take out the frequency converter 8 with fittings 8D c The bowl detector switch 12 can be taken o...

Page 16: ...16 Cabling diagram RN20 194 39M RN20 194 19M RN20 194 29M RN20 194 25M RN20 194 15M RN20 194 26M RN20 194 16M RN20 194 27M RN20 194 17M RN20 194 37M RN20 194 28M CR10 194 39M ...

Page 17: ...7M Cable for safety circuit VL2 W4 RN20 194 28M Emergency stop cable Frequency inverter VL2 W5 RN20 194 39M Connunication cable VL2 W6 RN20 194 19M Connunication cable VL2 W7 RN20 194 29M Connunication cable VL2 W8 RN20 194 27M Safety cable Frequency inverter VL2 W9 RN20 194 37M Cable for guard micro VL2 W10 RN20 194 26M Motor Cable Frequency inverter VL2 W11 RN20 194 16M Motor Cable 3 Phases VL2 ...

Page 18: ...e que le batteur mélangeur ci dessous Verklaart hiermede dat Menger Declaramos que el producto batidora er i overensstemmelse med relevante bestemmelser i Maskindirektivet Direktiv 2006 42 EC is in conformity with the relevant provisions of the Machinery Directive 2006 42 EC konform ist mit den Bestimmungen der EG Maschinenrichtlinie Direktiv 2006 42 EG Satisfait à l ensemble des dispositions pert...

Page 19: ...a presente si dichiara che questo mixer planetaria Deklareerime käesolevaga et Planetaarmikseri Niniejszym oświadczamy że mikser planetarny vakuuttaa että tämä mikseri tyyppi överensstämmer med tillämpliga bestämmelser i maskindirektivet 2006 42 EG is è conforme alle disposizioni della Direttiva Macchine Direttiva 2006 42 CE vastab kehtivatele masinadirektiivi 2006 42 EÜ nõuetele spełnia wymagania...

Page 20: ...20 Varimixer A S Kirkebjerg Søpark 6 DK 2605 Brøndby Denmark Telefon 43 44 22 88 info varimixer com www varimixer com ...