SAFETY:

User safety is assured as follows:

The mixer is designed for commercial use in kitchens, catering outlets and bakeries.

The machine is designed for the manufacture of products that do not trigger any reactions or release substances 

that may be harmful to the user when in use.

The machine must not be used in an explosive atmosphere.

The machine may only be used by trained personnel.
 Always comply with local laws and regulations with special attention to operators age, physical and mental condi-

tion. Operator must be over 14 years of age. 

The constant noise  level of the workplace of the operator is lower then 70 dB (A)
Tools can only rotate when the safety guard is in place and the bowl is lifted (bowl detection).
The safety guard is made of plastic. 
It is not possible to attach the guard incorrectly.
No access to rotating tools.

The spread of flour dust is inhibited.
Equipped with emergency stop - The tool stops rotating in less than 4 seconds (also for normal shut-down and 

stop via safety guard).

Clearance between guard/stand and lifting handle at least 50 mm.

Machine remains stable even if tilted of up to 10°. 
The machine is protected against overvoltage.

Non-ionising radiation

 is not produced intentionally, but rather technically conditioned by electrical equipment (e.g. elec-

tric motors, live power lines or solenoids). The machine is equipped with strong permanent magnets. By maintaining a safe 

distance (between the field source and implant) of 30 cm, any impact on active implants (e.g. pacemakers, defibrillators) 

can likely be prevented.

 

Magnets: 

Warning for users with implants (e.g. pacemakers, defibrillators).

machine and safety guard equipped with strong magnets

Areas on machine and 

bowl with magnets - 

for bowl detection

Area on safety guard with magnets

Area on machine with 

magnets - for safety 

guard switch

Summary of Contents for KODIAK10

Page 1: ...Varimixer A S Kirkebjerg S park 6 DK 2605 Br ndby Denmark P 45 4344 2288 E info varimixer com www varimixer com KODIAK KODIAK10 EN DRN 20010 1602 Original user manual 2021 04 22 Operating Instructions...

Page 2: ...The guarantee does not cover damage caused by misuse overloading or the user s failure to comply with the maintenance instructions Unpacking The machine should be unpacked and the packaging disposed o...

Page 3: ...sitioned uppermost on the back of the machine The electrical installation circuit must be secured by a Residual Current Device RCD type A SI The mixer must be earthed Failure to do so may cause Risk o...

Page 4: ...y No access to rotating tools The spread of flour dust is inhibited Equipped with emergency stop The tool stops rotating in less than 4 seconds also for normal shut down and stop via safety guard Clea...

Page 5: ...designed for Kodiak may be used Keep hands out of the bowl while the machine is running can cause severe injury Unless the change is recommended by the manufacturer modifying the machine is prohibite...

Page 6: ...afety guard Mixer head Adjustable legs see page 3 for adjustment Components of the machine When lifted the bowl should be fixed underneath the bowl fitting The bowl must be pushed all the way into the...

Page 7: ...nd intuitive with large push buttons The panel is easy to clean with a damp cloth There is a built in timer function with a display which can also be used to show the number of operating hours Bowl Th...

Page 8: ...ok whip beater scraper with standard blade Optional accessories Scraper blade for high temperature products PTFE Tool rack Equipment Correct use of tools Recommended uses of tool The whip should not b...

Page 9: ...onds in the timer field between and Running times of up to 90 minutes are available When the mixer is running the running time will not be reset if is pressed once press once more and it will be reset...

Page 10: ...ee bearings and should therefore not be lubricated Cleaning The machine may only be cleaned by trained staff and must be over 14 years of age Before any cleaning unplug the machine to prevent electric...

Page 11: ...should be on the machine and be intact Daily The rubber plug must cover the opening on the attachment drive when the latter is not in use Cleaning Follow the instructions in the section Cleaning Follo...

Page 12: ...quency converter Solution Call the engineer Thermal sensor in the frequency converter has cut out Solution The error will disappear when the temperature has dropped to an acceptable level Intermittent...

Page 13: ...total running time of 21 232 min Data set 4 States the number of times the machine has been disconnected from the power supply plug pulled out of the machine powercut switched off and restarted displa...

Page 14: ...Page Project rev Case no Project title CR10 VL1C 200 230V N PE 11 PCSCHEMATIC Automation 1 2 3 4 5 6 7 8 F1 Fuse 10A 14 Circuit diagram 110 230V R1 Ground choker 100 120V only...

Page 15: ...Menger Declaramos que el producto batidora er i overensstemmelse med relevante bestemmelser i Maskindirektivet Direktiv 2006 42 EC is in conformity with the relevant provisions of the Machinery Direc...

Page 16: ...Varimixer A S Kirkebjerg S park 6 DK 2605 Br ndby P 45 4344 2288 E info varimixer com www varimixer com...

Reviews: