11
Part
Action
Frequency
Note
Safety guard
Check the safety of the safety guard:
Does the tool stop rotating, when
the safety guard is not positioned
correctly?
Regularly
If the tool does not imme-
diately stop rotating when the
safety guard is not positioned
correctly, the machine must
not be used.
Call the engineer
Emergency stop
Test the emergency stop: Does the
tool stop rotating when the emergen-
cy stop is activated
Regularly
If the tool does not imme-
diately stop rotating on activa-
tion of the emergency stop, the
machine must not be used.
Call the engineer
Attachment drive
The rubber plug for covering the
opening of the attachment drive
should be on the machine and be
intact.
Daily
The rubber plug must cover
the opening on the attachment
drive when the latter is not in
use.
Cleaning
Follow the instructions in the section
“Cleaning”
Follow the instructions
in the section “Clea-
ning”
Systematic maintenance:
Local 50/60 Hz supply.
Name plate
Power supply:
phases x voltage
With
neutral
Earth
Voltage Phases
Use
neutral
Use
earth
Notes
1 x 220-240V
Neutral
yes
230V
1
yes
yes
Note that the machine must not be
connected without an earth, as this may
compromise the action of the EMC filter
by removing the discharge to the ground,
and may be dangerous for the user.
For functional and safety rea-
sons, the machine must be
connected to the earth.
2 or 3 x 220-240V
-
yes
230V
2
-
yes
2 or 3 x 380-415V
Neutral
yes
230V
1
yes
yes
2 or 3 x 380-480V
-
yes
380-480V
2
-
yes
Example electrical connections: