Commissioning:

Bowl, tools and safety guard should be cleaned before use – see section on 

Cleaning, page 10.

The machine should be positioned to allow space for normal use and maintenance.

.

use of the machine:

The machine may only be used as specified in this manual.

Only bowls designed for Kodiak may be used.

Keep hands out of the bowl while the machine is running, can cause severe injury.

Unless the change is recommended by the manufacturer, modifying the machine is prohibited.

The following recommendations apply to work with powdery ingredients:

•  Powdery ingredients should not be poured into the bowl from a great height. 
• 

Bags of e.g. flour should be opened at the bottom and down in the bowl.

Technical data:

Kodiak 10

Gross weight

Net weight

Power

Variable speed, tool

Model

kg

kg

kW

rpm

Floor model

138

120

0,7

72 - 451

Table model

63

50

Summary of Contents for KODIAK10

Page 1: ...Varimixer A S Kirkebjerg S park 6 DK 2605 Br ndby Denmark P 45 4344 2288 E info varimixer com www varimixer com KODIAK KODIAK10 EN DRN 20010 1602 Original user manual 2021 04 22 Operating Instructions...

Page 2: ...The guarantee does not cover damage caused by misuse overloading or the user s failure to comply with the maintenance instructions Unpacking The machine should be unpacked and the packaging disposed o...

Page 3: ...sitioned uppermost on the back of the machine The electrical installation circuit must be secured by a Residual Current Device RCD type A SI The mixer must be earthed Failure to do so may cause Risk o...

Page 4: ...y No access to rotating tools The spread of flour dust is inhibited Equipped with emergency stop The tool stops rotating in less than 4 seconds also for normal shut down and stop via safety guard Clea...

Page 5: ...designed for Kodiak may be used Keep hands out of the bowl while the machine is running can cause severe injury Unless the change is recommended by the manufacturer modifying the machine is prohibite...

Page 6: ...afety guard Mixer head Adjustable legs see page 3 for adjustment Components of the machine When lifted the bowl should be fixed underneath the bowl fitting The bowl must be pushed all the way into the...

Page 7: ...nd intuitive with large push buttons The panel is easy to clean with a damp cloth There is a built in timer function with a display which can also be used to show the number of operating hours Bowl Th...

Page 8: ...ok whip beater scraper with standard blade Optional accessories Scraper blade for high temperature products PTFE Tool rack Equipment Correct use of tools Recommended uses of tool The whip should not b...

Page 9: ...onds in the timer field between and Running times of up to 90 minutes are available When the mixer is running the running time will not be reset if is pressed once press once more and it will be reset...

Page 10: ...ee bearings and should therefore not be lubricated Cleaning The machine may only be cleaned by trained staff and must be over 14 years of age Before any cleaning unplug the machine to prevent electric...

Page 11: ...should be on the machine and be intact Daily The rubber plug must cover the opening on the attachment drive when the latter is not in use Cleaning Follow the instructions in the section Cleaning Follo...

Page 12: ...quency converter Solution Call the engineer Thermal sensor in the frequency converter has cut out Solution The error will disappear when the temperature has dropped to an acceptable level Intermittent...

Page 13: ...total running time of 21 232 min Data set 4 States the number of times the machine has been disconnected from the power supply plug pulled out of the machine powercut switched off and restarted displa...

Page 14: ...Page Project rev Case no Project title CR10 VL1C 200 230V N PE 11 PCSCHEMATIC Automation 1 2 3 4 5 6 7 8 F1 Fuse 10A 14 Circuit diagram 110 230V R1 Ground choker 100 120V only...

Page 15: ...Menger Declaramos que el producto batidora er i overensstemmelse med relevante bestemmelser i Maskindirektivet Direktiv 2006 42 EC is in conformity with the relevant provisions of the Machinery Direc...

Page 16: ...Varimixer A S Kirkebjerg S park 6 DK 2605 Br ndby P 45 4344 2288 E info varimixer com www varimixer com...

Reviews: