15
Error description
Action
EE01
Start is pressed without the bowl being raised to working
height
Raise the bowl to working height
EE02
Start is pressed without the safety guard fitted
Mount and close the safety guards.
Double press
to reset alarm
EE03
Bowl not detected
Check if the bowl is positioned correctly - (It is possible to
lower the bowl even if the error code is displayed).
If/when the bowl is positioned correctly, it is pushed all the way
back into the bowl arms, the sensor is thereby activated and
the bowl can be lifted.
If the contact between sensor and bowl is broken again, the
error code is displayed.
During the first 5 seconds when the error code is displayed, it
is possible to continue lifting the bowl, after which the lifting
movement stops. The bowl is pushed all the way back into
the bowl arms so that the contact between bowl and sensor is
re-established. The error code disappears and the bowl can be
lifted again.
EE04
Motor thermal sensor
Read Error codes for FI for detailed error description.
Wait with further operation until the engine temperature has
dropped to a level where the machine can be restarted.
Check main engine external ventilation is working properly.
Reduce the load and/or the machine’s ambient temperature.
EE05
Overload switch for lift motor
Check whether the lifting actuator has moved past switch and
hits the fixed end stop.
Detach lift actuator from bowl arms. Check friction between
bowl arms and shaft is OK.
Check lifting actuator without it fitted to bowl arms.
EE06
The control panel has lost connection to the frequency inverter
Call a technician.
The cause may be a fault in the wiring, control panel or fre-
quency inverter.
EE07
Fault in the internal speed drive
Call a technician.
Read Error codes for FI for detailed error description.
EE08
Thermal sensor in internal speed drive
Read Error codes for FI for detailed error description.
The fault disappears when the temperature has dropped.
Reduce load, and/or machine’s ambient temperature.
EE09
Too low voltage
Voltage must be checked by a technician.
Read Error codes for FI for detailed error description.
EE10
High supply voltage is periodically detected
Read Error codes for FI for detailed error description.
Call a technician.
Check power supply
EE15
2-hand sync error
See operating instructions for guidance.
Call a technician.
Error on the buttons for bowl lift
OL01
Continuous overload
Read Error codes for FI for detailed error description.
Procedure in case of overload
• Press emergency stop
• Open the security screen
• Reduce the content in the bowl
• Close the safety guard and release the emergency stop.
After a short time, the display switches back to normal mode
and the machine can be started again.
OL02
Periodic overload
OL03
Blocked
Less than 100 rpm and full torque
Error codes machine
ELECTRICAL DOCUMENTATION
Contact the dealer if electrical documentation is required.