4.2 MACHINE LOG
Horizontal -
• Read operating data in the selected time interval
- Log data is read in intervals:
- 0:00-23:59 shows data for the current day
- Mon-Sun shows data for the current week
- Month shows data for the current month
- Total shows data from the machine’s first start
Vertical -
• Number of starts shows the number of times the machine has
been started
• Operating time shows the number of hours the machine has
been operating
• Number of alarms shows the number of cases an alarm has
been activated
• Number of maximum engine loads shows the number of
cases where the load of the motor has been loaded to max or
overloaded
• Number of maximum temperature frequency inverter, is the
number of cases where the temperature of the frequency
inverter has been too high
• Max motor current shows the maximum load on
the frequency inverter in %. Max value is 180%
• Max engine temperature shows the maximum temperature
the engine has achieved measured in °C
5.1 DEFAULT SETTINGS
• Press PIN code for off/on PIN code protection when changing
recipes
- for changing the PIN code, the code is: 2345
• Access to Basic Settings requires the factory PIN code.
In Basic settings, set up e.g. frequency inverter parameters and
screen settings.
• Setting the time and date. Press time/date to open panel for
changing time and date.
5.0 LANGUAGE
• Press the desired flag for language selection
• Press Default settings to access PIN code, setup, and mixer
basic settings.