CPS-2C USER’S GUIDE
Section C-34
CPS-2C
(POS 7)
PROBE 1 MIN
Probe 1 Minimum
—
-58.0 to 140.0
°
F
(-50.0 to 60.0
°
C)
Or
-0.500’’H
2
O to 0.500’’H
2
O
[F2] –
Lo AL
– Low Alarm 1
-10.0
°
F (-5.6
°
C)
Or
-0.100’’H
2
O
-40.0 to -0.5
°
F (-22.2 to -0.3
°
C)
Or
-0.500’’H
2
O to 0.000’’H
2
O
[F2] –
A...CODE
– Alarm Code
—
See parameter description
(POS 8)
PROBE 1 MAX
Probe 1 Maximum
—
-58.0 to 140.0
°
F
(-50.0 to 60.0
°
C)
Or
-0.500’’H
2
O to 0.500’’H
2
O
[F2] –
Hi AL
– High Alarm 1
10.0
°
F (5.6
°
C)
Or
0.100’’H
2
O
0.5 to 40.0
°
F (0.3 to 22.2
°
C)
Or
0.000’’H
2
O to 0.500’’H
2
O
(POS 9)
CLOSE TIME 1
Close Time 1
3 seconds
1 to 120 seconds
[F2] –
OFF D
– Close Delay 1
120 seconds
5 to 600 seconds
(POS 10)
OPEN TIME 1
Open Time 1
3 seconds
1 to 120 seconds
[F2] –
OFF d
– Open Delay 1
120 seconds
5 to 600 seconds
(POS 11)
MAIN SET
POINT 1
Main Set Point 1
67.0
°
F (19.4
°
C)
Or
0.070’’H
2
O
-40.0 to 100.0
°
F
(-40.0 to 37.8
°
C)
Or
0.000’’H
2
O to 0.500’’H
2
O
[F2] –
DIFF
:
– Differential 1
2.0
°
F (1.1
°
C)
Or
0.020’’H
2
O
0.5 to 20.0
°
F (0.3 to 11.1
°
C)
Or
0.000’’H
2
O to 0.050’’H
2
O
[F2] – Inlet 1 Manual Operation
AUTO
AUTO, HOLD, CLOSE, HOLD,
OPEN
(POS 12)
PROBE 1
Probe 1 Readout
—
-58.0 to 140.0
°
F
(-50.0 to 60.0
°
C)
Or
-0.500’’H
2
O to 0.500’’H
2
O
LO
REC
HI
REC
TIMER
on
off
TIMER
on
off
Summary of Contents for CPS-2C
Page 3: ...CPS 2C WIRING DIAGRAM CPS 2C Section A 3 WIRING DIAGRAM CPS 2C SECTION A ...
Page 7: ...CPS 2C INSTALLATION CPS 2C Section B 7 INSTALLATION CPS 2C SECTION B ...
Page 20: ...CPS 2C USER S GUIDE Section C 20 CPS 2C USER S GUIDE CPS 2C SECTION C ...
Page 38: ...CPS 2C INDEX WARRANTY INDEX WARRANTY CPS 2C SECTION D ...