34A
Signify Classified - Internal
7. How To Control The Unit
You can operate the unit by DMX controller.
7.1 DMX512 Configuration
16Bit EN Channel Mode (Default mode):
CHANNEL
VALUE
DEFAULT
FUNCTION
1
0-65535
0
Intensity High
16 Bit control of Dimming
2
0-65535
0
Intensity Low
16 Bit control of Dimming
3
0-65535
32767
Pan High
540° Total Pan Rotation
4
0-65535
32767
Pan Low
540° Total Pan Rotation
5
0-65535
32767
Tilt High
270° Total Tilt
6
0-65535
32767
Tilt Low
270° Total Tilt
7
0-65535
32767
Focus High
Focus control, default value 50% focus range
8
0-65535
32767
Focus Low
Focus control, default value 50% focus range
9
0-65535
32767
Zoom High
Zoom control, default value 50% zoom range
10
0-65535
32767
Zoom Low
Zoom control, default value 50% zoom range
11
0-255
0
Cyan
Cyan Color Control 0-100% saturation
12
0-255
0
Yellow
Yellow Color Control 0-100% saturation
13
0-255
0
Magenta
Magenta Color Control 0-100% saturation
14
0-255
0
CTO Wheel
CTO Color Control 0-100% saturation
15
0-255
0-30
31-60
61-90
0
Color Adjustment (Color Wheel 2)
Open
CRI Booster
1/4 Minus Green