CONNECTING DATA AND POWER
A maximum of 32 luminaires may be connected in any one DMX data link.
A maximum of 9 luminaires may be connected in 120V, 60Hz.
A maximum of 16 luminaires may be connected in 230V, 50Hz.
NOTE:
This maximum limit applies to the luminaire “daisy chain” only. Your system or console may require few-
er luminaires on a single data link path. Consult your console documentation for more information.
To connect power and data:
Step 1.
Connect data cable from console to first luminaire in chain at DATA IN connector.
Step 2. If required, connect additional data cables from DATA THRU connectors to DATA IN connectors of
remaining luminaires in link.
Step 3. At last luminaire in link, install male termination connector at DATA THRU connector. (Luminaires and
other devices on the same DMX chain may not function properly without termination.)
Step 4. Connect AC Input Cable connector to power input source.
Step 5. Dress AC input and data cables and secure them so that they will not interfere with luminaire head
and yoke movement.