72
VMM3120
Tests
List of Deviations
Ref. # Initial Requirement
Deviation
Reason
1
Min temp: -40 °C
Max temp: +120 °C
Min temp: -40 °C
Max temp: +85 °C
Design limitation
8
Distance to the UUT
75 cm
Distance to the UUT
50cm
Equipment deviation
15
Rate of voltage
change:1V/ms
Actual rate: 1V/s
Not able to monitor
impaired function during
milliseconds.
17
48 V
36 V
Design limitation
19
16 V
32 V
Unit is designed as
12V/24V product. 32V is
more appropriate level.
21
Source impedance 15
Source impedance 10
Equipment limitations
21
Repetition rate 0.2Hz
Repetition rate 0.02Hz
Equipment limitations
22
6 + |12.6sin(2pft)|
12 + |25.2sin(2pft)|
22
Frequency range:
500Hz-1.5kHz
Frequency range:
800Hz-1.5kHz
Equipment limitations
23/
24
24V system: V=600V
24V system: V=500V
UUT is 24V system
28/
29
Test bench size:
2500mmx900mm
Test bench size:
1800mmx800mm
Equipment limitations
28/
29
UUT and antenna
minimum distance from
the enclosure: 2m (walls
and ceiling)
Actual enclosure size:
3.05x3.05
Biconical Antenna width:
1.35m
Log periodic antenna length:
75cm
Equipment limitations
28/
29
UUT and antenna
minimum distance from
absorber:1m
Actual enclosure size:
3.05x3.05
Biconical Antenna width:
1.35m
Log periodic antenna length:
75cm
Equipment limitations
30/
31
C=250pF
C=330pF
Harsher test
30/
31
UUT positioned on a
static dissipative mat
UUT positioned on a piece
of dielectric foam
ISO 10605 requirement
Summary of Contents for VMM3120
Page 1: ...Vansco Multiplexing Module VMM3120 User Guide HY33 5004 IB US UG VMM3120 0916014 201705 002...
Page 10: ......
Page 14: ...4 VMM3120 About the VMM3120 Symbol Meaning Fuse Resistor Ground Chassis ground...
Page 89: ...User Guide 79 Glossary...
Page 92: ...Vansco Multiplexing Module VMM3120 User Guide HY33 5004 IB US...