User Guide
29
Outputs
When a high-side output is used as an on/off signal, the output provides
battery voltage when in the on state (the application software is responsible
for switching high-side outputs on and off).
The following table provides specifications for the VMM3120's high-side outputs:
High-Side Output Specifications
Item
MIN
NOM
MAX
UNIT
Switchable voltage range
6
-
32
V
Output current
0
-
2.5
A
Output on state resistance
-
90
-
mΩ
Load resistance (12 V system)
6.4
-
-
Ω
Load resistance (24 V system)
12.8
-
-
Ω
Over-voltage
-
-
36
V
PWM frequency
-
-
500
Hz
PWM resolution
-
-
0.1
%
Inductive pulse protection
-
-
628
V (peak)
Digital feedback minimum negative going threshold
1.56
-
-
V
Digital feedback minimum positive going threshold
-
-
3.65
V
Open load detection resistance
10
-
-
kΩ
4.1.2. High-Side Output Configuration
For software-controlled open load detection, the programmer has the ability to
choose when to bias the output through
the open load detection resistor. This
feature may be disabled by the programmer using software if the output is
connected to sensitive loads, such as LEDs.