A-4
Specifications
Data 1 and Data 2 Cable Descriptions
Data 1 and Data 2 Cable Descriptions
Introduction
Each Vanguard 650 Series product has two Data connectors located at the rear of the
unit. One of these connectors, labeled Data 1, is an RJ45, and the other connector,
labeled Data 2, is a DB25 female.
Data 1 (RJ45) Port
Cable Pinout
The connector pins of the Data 1 port are numbered from left to right as indicated in
the following diagram:
Data 1 (RJ45) Port
EIA-232 Cable
Pinout
For the 651/653 product, this port can be used to connect an EIA-232 device, using
the following pinout for the RJ45 jack:
Note
You can use the DB25 to RJ45 cable (part number 68361) to access the sync
port.
Pin 8
Pin 1
Interface Signal Name
Pin #
EIA
ITU-T V.24
1
TxD
103
2
Signal Ground
102
3
TxC
114
4
RTS
105
5
RxC
115
6
DTR
108
7
RxD
104
8
CTS
106