RS-232 CONTROL
Set the parameters (baud rate, data bit, stop bit and parity bit) correctly to ensure reliable RS-232 control.
Baud rate: 9600
Data bit: 8
Stop bit: 1
Parity bit: none
•
“[“, “]” in the commands are for easy recognition only and not necessary in real operations. Other
symbols including “.”, “,”, “/”, “%”, “;”, “^”. are parts of the commands.
•
Feedback listed in the column “Feedback Example” are only for reference, feedback may vary according to
different operations.
•
Dial the EDID switcher to “1111” before sending commands pertaining to software EDID management
(with gray background).
Visit the product page at www.vanco1.com for additional product commands and downloads.
TCP/IP CONTROL
Control Mode
TCP/IP Control allows for the matrix unit to be controlled remotely using any device that is on the same
network as the matrix unit is connected to. Simply connecting an ethernet switch or router to the TCP/IP port
on the backside of the matrix allows for this. The matrix unit will now be accessible by entering the IP address
in any browser.
TCP/IP default settings: IP is 192.168.0.178
Gateway is 192.168.0.1
Serial Port is 4001.
This is the default IP address the matrix unit will utilize, this can be changed manually. If there are issues
connecting to the matrix unit using the default IP address listed above, ensure that no other component within
the network is using the same IP address.