background image

www.vanco1.com

800.626.6445

10

Controlled by single PC

1.  Connect a computer to the TCP/IP port of the Matrix Switcher and set its network segment to the same 

as the default IP of the Matrix Switcher (192.168.0.178).

2.  Change the IP of the PC

Controlled by PC(s) in LAN

1.  Connect the TCP/IP port of the Matrix Switcher to Ethernet port of PC using a Category (Cat5e/6) cable.
2.  Set the PC’s network segment to the same as the Matrix Switcher. Record the PC’s original network 

segment.

3.  Set the Matrix Switcher’s network segment to the same as the router.
4.  Set the PC’s network segment to the original segment.
5.  Connect the Matrix Switcher and PC(s) to the router. In the same LAN, each PC should be able to control 

the Matrix Switcher simultaneously.

The Matrix Switcher can be connected to a router or switch. This allows for the matrix unit to be controlled 
over TCP/IP. When controlling the matrix unit with this method, ensure the network segment is the same as 
the router. See below for connection diagram using this method:

Summary of Contents for Evolution EVMX4K44

Page 1: ...Vanco Part Number EVMX4K44 HDMI 4 x 4 4K Matrix Selector Switch www vanco1 com 800 626 6445 HDMI 4x44K MA TRIX Supports 4K 60Hz 4 4 4 Chroma and HDR ...

Page 2: ...cularly at the plugs 9 Use unit only with accessories specified by the manufacturer 10 Refer all servicing to qualified personnel CAUTION HDMI is a very complex technology requiring continuous authentication of the signal and the same video resolution and audio settings on all electronic equipment in the system When there are multiple sources and displays the video resolution and audio setting on ...

Page 3: ...to interface with third party audio systems For reliable HDMI distribution with 4K and HDR in mind the EVMX4K44 is a great choice for any application FEATURES HDMI 4 x 4 4K Matrix Selector Switch Part EVMX4K44 Allows up to 4 HDMI sources to be distributed simultaneously to up to 4 displays Supports up to 4K 60Hz 4 4 4 and HDR Supports both HDR10 and Dolby Vision HDCP 2 2 HDCP 1 4 compatible Suppor...

Page 4: ... Audio Signal HDMI or DVI D Resolution Range Dolby Digital DTS DTS HD EDID Management Built in EDID data and manual EDID management Resolution Range 640x480 60Hz 4K 60Hz 4 4 4 1080p 3D Bandwidth 18 Gbps Switching Speed 200nz Max EDID Management In built EDID data and manual EDID management HDMI Cable Length Less than 5m Power Supply 124VDC 1 25A Power Consumption 14W max Temperature 0 40 degree C ...

Page 5: ...nges for INPUT OUTPUT selection or EDID adjustments 9 HDMI Inputs Inputs 1 4 connect source s 10 HDMI Outputs Outputs 1 4 connect display s 11 Control A EDID dip switch See EDID section for adjustment and operation B RS 232 Port Serial control and 3rd party integration C IR IN 3 5mm jack to connect to included IR RX cable for IR control unit can be hidden and can still be controlled using this cab...

Page 6: ...ect an RS 232 cable from the RS232 port on the matrix to a third party control system 4 OPTIONAL Connect third party audio systems via SPDIF audio outputs 5 Connect the included DC 24V Locking power supply 6 Power up the EVMX4K44 and then the components connected NOTE Ensure cabling is 2 0 compliant or HDMI certified for the best 4K resolution display For audio outputs connect amplifiers or compon...

Page 7: ...shows each combination based on the dip switch adjustments from 1 4 see rear side of the EVMX4K44 for the EDID dip switches Simply adjust to On or Off for all four switches To make and EDID adjustment power off the EVMX4K44 adjust the dip switches and then power on the unit for changes to take effect A successful adjustment will result in picture being displayed Switching Status Query Press OUTPUT...

Page 8: ...n order to send an input to all outputs splitting signal To send a single input to all outputs Example Input 1 to all Outputs Press INPUT 1 then ALL then ENTER EDID MANAGEMENT BUTTON 1 One input port learns the EDID data from a specific output port Example Input 2 learns EDID data from output 4 Press EDID then INPUT 2 then OUTPUT 4 then ENTER 2 All input ports learn EDID data from one specific out...

Page 9: ...e at www vanco1 com for additional product commands and downloads TCP IP CONTROL Control Mode TCP IP Control allows for the matrix unit to be controlled remotely using any device that is on the same network as the matrix unit is connected to Simply connecting an ethernet switch or router to the TCP IP port on the backside of the matrix allows for this The matrix unit will now be accessible by ente...

Page 10: ...as the Matrix Switcher Record the PC s original network segment 3 Set the Matrix Switcher s network segment to the same as the router 4 Set the PC s network segment to the original segment 5 Connect the Matrix Switcher and PC s to the router In the same LAN each PC should be able to control the Matrix Switcher simultaneously The Matrix Switcher can be connected to a router or switch This allows fo...

Page 11: ...ch on UPnP protocol 1 Add UPnP component go to Control Panel double click Add Delete Programs double click Add Delete windows component tick UPnP click Next click OK 2 Enable Windows Firewall go to Control Panel double click Windows Firewall click Others tick UPnP framework 3 Enable UPnP auto starting go to Control Panel double click Administrative Tools double click Services find and click SSDP D...

Page 12: ... displays every possible connection between every input and output users can carry on the connections by clicking corresponding button Buttons 1 9 at the right bottom corner provides quick saving and recall for overall connection status User Tab The main tab allows for switching inputs to outputs using a grid format simply select the input and output combination desired ...

Page 13: ...he front panel and also allows for changing the name of the inputs and outputs for easier input output switching Configuration Tab The configuration tab allows for switching on off the SPDIF digital audio output for every output and also manages EDID See the screenshot below 1 Audio Out Switch on off audio for every output ...

Page 14: ...www vanco1 com 14 2 EDID Copy One or multiple inputs received EDID info from one specific output 3 EDID Setting Select the built in EDID for every input Choose from a list of default EDID combinations ...

Page 15: ...the Matrix Switcher supports online updating enter the following URL http 192 168 0 178 100 in any browser Type the username and password the same as the UI log in settings modified password will be available only after rebooting to log in the configuration interface Then click Administration at the source menu to get to Upload Program as shown below ...

Page 16: ... log in the WebServer User admin Password admin Firmware Update The matrix switcher also has a USB port for online firmware upgrade on the front panel Follow these steps to upgrade firmware 1 Copy the upgrade software and the latest upgrade file bin to PC 2 Connect the USB ports of the matrix switcher and the PC via USB cable 3 Double click the update software icon see as below The following promp...

Page 17: ...uttons are locked Send command Unlock to unlock Cannot control the device via IR remote The battery has run off Change for new battery The IR remote is broken Send it to authorized dealer for repairing Beyond the effective range of the IR signal or not pointing at the IR receiver Adjust the distance and angle and point right at the IR receiver Power Indicator remains off when powered on Fail or lo...

Page 18: ...e from defects in materials and workmanship for a period of two years from the date of purchase Should this product in Vanco s opinion prove defective within this warranty period Vanco at its option will repair or replace this product without charge Any defective parts replaced become the property of Vanco This warranty does not apply to those products which have been damaged due to accident unaut...

Page 19: ...ce available for reference during the call Please read this Instruction Manual prior to calling or installing this unit since it will familiarize you with the capabilities of this product and its proper installation All active electronic products are 100 inspected and tested to insure highest product quality and trouble free installation and operation The testing process utilizes the types of high...

Page 20: ...Vanco International 506 Kingsland Drive Batavia Illinois 60510 call 800 626 6445 fax 630 879 9189 visit www vanco1 com ...