SECTION 7: TROUBLESHOOTING
AIR IN ARC
®
300 SERIES ALL-IN-ONE POWER SYSTEM
®
PAGE - 114
090012-OP_r0
WELDER (CONTINUED)
No welder output in CC mode
Bad ground connect
Make sure of connection. Clean welding
surface.
Faulty electrical circuit
Check electrical circuit.
GENERATOR
No AC generator output
Serpentine belt slipping or damaged
Re-situate and adjust belt tension, or
replace belt if necessary. Consult
Section
6.6.15, Replacing and Re-tensioning the
Serpentine Belts
. Order replacement
belt—see
Table 9A: Recommended Spare
Parts List
.
Faulty AC generator relay
Check; replace if necessary.
Faulty capacitor
Check; replace if necessary.
Low AC voltage
Engine speed too low for demand
Adjust speed control. Consult
Section
6.6.13, Adjusting the Engine Speed
, and
the Engine Operator’s Manual.
Weak or faulty capacitor
Check; replace if necessary.
Belt slipping
Check tension or replace belt ifnecessary.
Consult
Section 6.6.16, Replacing and Re-
tensioning the Serpentine Belts
. Order
replacement belt—see
Table 9A: Recom-
mended Spare Parts List
.
High AC voltage
Engine speed too high for demand
Adjust speed control. Consult
Section
6.6.13, Adjusting the Engine Speed
, and
the Engine Operator’s Manual.
7.2 TROUBLESHOOTING GUIDE
Fault/Malfunction
Possible Cause
Corrective Action