V-460G/610G
Series Operating Instructions Ver.4.02E
66
[
x x
]▼▲CHG Move N
x
1V MANUAL G
x x
.
x
sec
HT
xx
O
C
x
.
x
s CT
xx
O
C
Display
Procedure
Section No. / Operation Method
1
Circuit breaker ON.
See "7-8 Turn ON the circuit breaker and power switch"
ĺSDJH23).
2
Power button ON.
See "7-8 Turn ON the circuit breaker and power switch"
ĺSDJH23).
3
3-a
Call up a pre-installed or registered operation
mode: “1-GAS manual.”
3-a
See 6HOHFWWKHGHVLUHGRSHUDWLRQQXPEHUĺ
page 40).
3-b
Register a new operation pattern.
3-b
See 5HJLVWHUFKDQJHWKHRSHUDWLRQSDWWHUQĺ
page 40).
Operation mode = “3 1-GAS”
Vacuum mode = “1Manual”
4
Set nozzle stroke.
[Setting range: N1 ~ N8 ]
See 6HWWLQJQR]]OHVWURNHĺSDJH56).
5
Set gas timer.
[Setting range: 0.1 ~ 99.9 seconds]
See 6HOHFWWKH*$6PRGHĺSDJH47).
6
Set heating temperature.
[Setting range: 60 ~ 250°C/ 140 ~ 480°F]
See 6HWKHDWLQJWHPSHUDWXUHĺSDJH41).
7
Set heating time.
[Setting range: 0.0 ~ 2.0 seconds]
See 6HWKHDWLQJWLPHĺSDJH42).
8
Set cooling temperature.
>6HWWLQJUDQJH%HWZHHQ&Û)DQG
the seal-heating temperature]
See 6HWFRROLQJWHPSHUDWXUHĺSDJH43).
9
Depress an air pedal. (1st)
7KHYDFXXPJDVÀXVKLQJQR]]OHVPRYHIRUZDUG
10
Place a pouch to the seal area.
Place a pouch to the seal area and insert the nozzles in it.
Stretch the pouch out by pulling both sides by hands.
8-5-5 Operation procedures «1-GAS: MANUAL VAC + GAS + SEAL»
Gas-flushing
timer
Operation No.
Nozzle stroke
Heat temp Heat time Cool temp
Vacuum mode:
manual
※
Temperature unit may be displayed in Fahrenheit
depending on the machine model.
Summary of Contents for V-460G Series
Page 105: ...V 460G 610G Series Operating Instructions Ver 4 02E 105 13 Electric diagram 110V ...
Page 106: ...V 460G 610G Series Operating Instructions Ver 4 02E 106 200 240V ...
Page 108: ...V 460G 610G Series Operating Instructions Ver 4 02E 108 V 460G 610G series H type models ...
Page 110: ...V 460G 610G Series Operating Instructions Ver 4 02E 110 V 460GC 610GC series H type models ...