5
9
6
8
7
10
12
Set heating temperature.
[Setting range: 60 ~ 250°C /140 ~
480°F]
Set the number of times for vacuum
DQGJDVÀXVKLQJ
[Setting range: 2 ~ 99 times]
6HWWKHQWKJDVÀXVKLQJWLPH
[Setting range: 0.0 ~ 99.9 seconds]
Set the n-1th vacuum time.
[Setting range: 0.1 ~ 99.9 seconds]
6HWWKHVWJDVÀXVKLQJWLPH
[Setting range: 0.1 ~ 99.9 seconds]
Set the 1st vacuum time.
[Setting range: 0.1 ~ 99.9 seconds]
Set cooling temperature.
[Setting range: 40
°
C/100
°
F ~ heating
temp. set value]
Refer to “CONTROL UNIT FC16(6)R Operating Instructions” >>> “4-2-5 Set
heating temperature.”
Refer to “CONTROL UNIT FC16(6)R Operating Instructions” >>> 4-2-16 Set
gas timer and the numbers of cycles for n-time gas mode.”
11
Set heating time.
[Setting range: 0.0 ~ 2.0 seconds]
Refer to “CONTROL UNIT FC16(6)R Operating Instructions” >>> “4-2-6 Set
heating time.”
Refer to “CONTROL UNIT FC16(6)R Operating Instructions” >>> “4-2-7 Set
cooling temperature.”
13
Depress a foot switch (1st).
A vacuum nozzle moves forward.
Place a pouch to the sealing area.
,QVHUWWKHYDFXXPQR]]OHLQVLGHWKHSRXFK:KLOHFRQ¿UPLQJWKHVHDOSRVLWLRQ
place the pouch to the seal area.
15
14
Depress the foot switch (2nd).
Pressure lever descends to clamp the pouch. Do not release the foot switch
until the lever descends completely.
LOS-NT/NTW series Operating Instructions Ver.6.02E
31
Attention
When the lever is being lowered, removing foot from the
footswitch will raise the lever from its lowered position.
Summary of Contents for LOS NT Series
Page 43: ...LOS NT NTW series Operating Instructions Ver 6 02E 43...
Page 53: ...LOS NT NTW series Operating Instructions Ver 6 02E 53 16 2 LOS NTW series piping diagram...
Page 57: ...LOS NT NTW series Operating Instructions Ver 6 02E 57...
Page 63: ...LOS NT NTW series Operating Instructions Ver 6 02E 63...