4.3.2
Assembling the air flow guide plates
To attach the guide plates to the Airmix, the
mounting bracket must first be attached to the fan.
One can also choose to attach the guide plates to the
mounting bracket before connecting the bracket to
the Airmix.
Requirements:
•
1x mounting bracket
•
4x hexagonal tap bolt m10 x 25
•
8 x washer m10
•
4x lock nut m10
The mounting bracket will be connected to the fan
according to Figure 16. Depending on the
configuration, the bolts passing through horizontal
strip of the mounting bracket will fixate either one or
two air flow guide plates.
Requirements:
•
1x Air flow guide plate
•
3x hexagonal tap bolt m5 x 16
•
6x washer m5
•
3x lock nut m5
When one air flow guide plate is connected to the mounting bracket, Figure 17 shows how it needs to
be assembled .
Figure 17 Connecting one air flow guide plate to mounting bracket
Figure 16 Assembling the mounting bracket