Van der Ende Groep · Aartsdijkweg 23, 2676 LE, Maasdijk · Tel. 0174 515050
IBAN NL71 RABO 0340341610 · KvK Den Haag 27230471 · Btw-nummer NL8000.78.378.B01 · [email protected] · www.vanderendegroep.nl
Page 15 of 32
4.2.2
Installing the condensate plate and fan
After the Airmix housing has been suspended, the condensate drip tray and the fan can be attached
to it. Depending on the type of fan, it is best to prepare this first; see chapter 6. To attach the fan and
condensate plate correctly, go through the following steps:
-
make sure you have the proper tools and equipment:
Quantity
Description
2
17mm open-ended wrench or socket wrench
-
make sure that the fan can be installed safely
–
get help if necessary;
-
what you will need for each Airmix:
Quantity Description
No. in
Article no. VDEG
1
Fan
21
720034XX
1
Condensate drip plate
22
72005120
8
m10 self-locking nut
23
56016220
12
m10 washer
24
56019220
2
m10x25 bolt
25
56013230
2
m10 nut st vz
26
56015220
-
attach the fan (21) to the Airmix housing by inserting it over the protruding M10 threads;
position the fan with the cable gland connection facing downward;
-
secure the fan to the upper six M10 threads with six M10 washers (24) and six M10 self-
locking nuts (23);
-
attach the condensate plate (22) to the Airmix housing by inserting it over the protruding M10
threads;
-
secure the condensate plate to the lower two M10 threads with two M10 washers (24) and
two M10 nuts (not self-locking nuts) (26);.
-
Secure the condensate plate to the fan with two M10x25 bolts (25), four M10 washers (24)
and two M10 self-locking nuts (23).
Figure 10 Installing the fan