Oil volume
When changing with filter
19
Viscosity grade should be selected depending on the temperature outside.
6.8.2
Fuel system
Fuel
Type
Diesel fuel which conforms to EN 590:2009 norm
Feed pump
Mechanical pump
Standard tank
380 liters
Forest tank
250 liters
Injection system
Common rail injection
High-pressure pump with electronic injection control
6.8.3
Selective catalytic reduction system
System type
Bosch DENOXTRONIC 2.2+
Fluid type
DIN70070/ISO22241-certified AdBlue/DEF
Tank capacity
70 liters
Forest tank capacity
45 liters
6.8.4
Air cleaner
Air cleaner
Two-stage, dry element, with blockage indicator
Pre-cleaner system
Ejector
6.8.5
Cooling system
Pump
Centrifugal
Radiator
Pressurised with expansion tank regulated by
pressure cap
Thermostat
2 thermostats: 79°C and 83°C
Fan
The belt-driven fan is controlled by the engine's
control module for precise fan speed modulation
Coolant
Engine coolant mixed with water. ASTM D6210 Type
I-FF, ASTM D3306.
In first fill, OAT-coolant (Organic Acid Technology)
used, not recommended to mix with old type of
coolants.
Coolant, Valtra grade
Valtra Coolant
Coolant volume
28 litres
6.9
Electrical system
Ground
Negative
Voltage
12 V
Battery
174 Ah
Table continued on next page
6. Technical specifications
- 389 -
Summary of Contents for T144
Page 1: ...OPERATOR SMANUAL TSERIES HiTech Ref no 39 892 21 3 08 2015 YOUR WORKING MACHINE...
Page 2: ......
Page 413: ......