Test-run the tractor.
4.6.2
Running the tractor in after a storing period longer than two
months
You must run the tractor in after a storing period longer than two months.
•
Check the tyre pressures.
•
Remove the protective covers from the exhaust pipe and air induction pipe.
•
Turn the radiator fan carefully forwards and backwards, so that the shaft
works loosely (it may be stuck to the sealing ring of the coolant pump).
•
Check that the engine air filters are undamaged.
•
Wash off any anti-corrosion oil applied to the exterior of the tractor.
•
Check the belts' tightness.
•
Check the oil level in the engine and transmission.
•
Check the coolant level in the radiator.
•
Refill the AdBlue/DEF tank with new AdBlue/DEF.
•
Change the selective catalytic reduction (SCR) system supply module main
filter.
•
Bleed the fuel system of air.
•
Refit the battery (fully charged).
IMPORTANT: Make sure that the main power is turned off before
disconnecting or reconnecting the battery.
•
Start the engine without racing it.
•
Test-run the tractor.
4.7
Periodical maintenance
5
20
30
40
50
0
5
0
20
25
30
1
GUID-56496CFD-9F29-4A47-9BBC-E980432028AF
1. Periodical maintenance view
4. Maintenance
- 265 -
Summary of Contents for T144
Page 1: ...OPERATOR SMANUAL TSERIES HiTech Ref no 39 892 21 3 08 2015 YOUR WORKING MACHINE...
Page 2: ......
Page 413: ......