38
Revision D November 2022
13) Cartridge Placement
To complete the assembly of a QuadGuard
®
HS system, place the appropriate Cartridge
in each Bay of the system as shown in Figure 41. The first two bays should not contain
Cartridges. Type I Cartridges are placed in Bays 3 and 4; Type II Cartridges are placed in
Bays 5 through 9.
Warning:
Placing a Cartridge in the first or second Bays, or placing a Cartridge
in the wrong Bay, may result in unacceptable crash performance as described in
NCHRP Report 350.
TYPE II CARTRIDGES
TYPE I CARTRIDGES
DO NOT PLACE
CARTRIDGES HERE
Figure 41
Cartridge Placement