Fill the engine with 1.7 L of SAE-10W-30 oil, then 

check the oil level until it marks just below “F”.  A 

funnel must be used to do this. Do not exceed the 

maximum capacity of 1.9L (2.0 qts.).

5

ELECTRIC START

MANUAL START

1

1

2

2

3

3

4

4

4

Do  the  same  steps  described  for  electric  start 

except step 4.

Pull one time with a slow 

and  controlled  move  to 

make  sure  there  are  no 

knots.  Make  a  quicker,    

stronger  pull  to  turn  on 

the  engine.  Repeat  this 

procedure as necessary. 

Fill the 6.6  gasoline tank 

with  a  clean,  new  85 

octanes or higher unleaded 

gasoline. A funnel must be 

used  to  avoid  gasoline 

spills  near  hot  areas.  It 

is  recommended  to  pour 

no  more  than  6  gallons 

of  gasoline  due  to  gases 

produced by gasoline when 

exposed to higher ambient 

temperatures.

Move  the  choke  lever  to 

the left to let the engine run 

at full speed (3600 rpm).

Turn  the  key  attached  to 

the  electric  start  to  the 

right  all  the  way  to  the 

“Start” position and hold it 

for  about  2-4  seconds.  If 

the engine does not start 

repeat  the  process  no 

more  than  5  times  in  30 

minutes.

Move the choke lever to 

the right

ASSEMBLY INSTRUCTIONS

Transporting handle

Tools  required:  7/16”  Spanner 

or wrench

 

Stationary foot

Tools required:  1/2” Spanner or 

wrench

Wheels and axle

Tools required: None

Battery holder

Tools  required:  7/16”  and  1/2”  Spanners  or 

wrenches

Summary of Contents for G8000 PRO

Page 1: ......

Page 2: ...placement parts SAFETY INFORMATION DANGER indicates a potentially hazardous situation which if not avoided WILL result in death or serious injury WARNING indicates a potentially hazardous situation wh...

Page 3: ...when it is running Check the fuel system periodically for leaks or signs of deterioration such as chafed or spongy hose loose or missing clamps or damaged tank or cap All defects should be corrected b...

Page 4: ...of voltage and 3 Hz of the rated values marked in the generator nameplate To avoid damage always have an additional no solid state load plugged into the generator if only solid state equipment such as...

Page 5: ...he tank This will allow fuel expansion during warm weather and so avoid spillage LUBRICATION DO NOT attempt to start the engine without filling the engine crankcase with the proper amount and type of...

Page 6: ...n one electric tool sum the amperes marked in the nameplates of each tool to determine the minimum cord gauge you need to use The extensions for 120 volts are made of 3 conductors where the green one...

Page 7: ...rea immediately get fresh air and SEEK MEDICAL TREATMENT To prevent serious injury or death from carbon monoxide NEVER run engine indoors Even if you try to ventilate the engine exhaust with fans or o...

Page 8: ...ble of the spark plug if engine is of electrical start before any inspection or maintenance Before each use review the general conditions of the generator Review that all pieces are complete Review if...

Page 9: ...RFORM BY ITSELF ANY PARTS REPLACEMENT OR REPAIRS TO THE PRODUCT ON PRINCIPLE BUYER AND OR END USER IS CONSIDERED BY THE MANUFACTURER UNQUALIFIED TO PERFORM BY ITSELF ANY REPAIRS OR PARTS REPLACEMENT T...

Page 10: ...HOUT NOTICE 10 ALTERNATOR SPARE PARTS NOTE Some parts are shown for illustration purposes only and are not available individually as replacement parts NOTE only a licensed electrician should perform e...

Page 11: ...SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 11 ASSEMBLY G80...

Page 12: ...r higher unleaded gasoline A funnel must be used to avoid gasoline spills near hot areas It is recommended to pour no more than 6 gallons of gasoline due to gases produced by gasoline when exposed to...

Page 13: ...nar el motor a velocidades demasiado altas Si se opera el motor a excesiva velocidad aumenta el riesgo de lesiones f sicas No toque o cambie piezas que puedan aumentar o disminuir la velocidad regulad...

Page 14: ...lido debe utilizarse un protector de sobrecarga para evitar posibles da os al equipo No coloque nada a trav s de las ranuras de ventilaci n a n cuando el generador no est en operaci n Esto puede da ar...

Page 15: ...determinadas condiciones Servicio continuo significa operaci n por periodos de unas cuantas horas en un evento no 24 horas al d a durante d as Tambi n implica alimentar una carga con FP unitario carg...

Page 16: ...n ngulo que force al nivel de aceite a cambiar Coloque el generador en una superficie plana y horizontal para corregir el problema Si el generador no arranca el nivel de aceite pudiera no ser suficien...

Page 17: ...nductores en donde el conductor verde es el conductor de la espiga de tierra el conductor blanco es la conexi n al neutro del generador y el conductor negro es el conductor vivo Las extensiones para s...

Page 18: ...un gas letal inodoro e invisible que se puede presentar aunque usted no vea o huela ning n escape de motor Niveles mortales de mon xido de carbono se pueden agrupar rapidamente y usted puede perder ha...

Page 19: ...intente realizar algunos de estos f ciles pasos antes de llamar a la l nea directa de informaci n de servicio al cliente Verifique el nivel de aceite Reemplace el combustible viejo Cambie la buj a de...

Page 20: ...o de la buj a tire del retr ctil varias veces y coloque la buj a Luego tire del arrancador hasta que sienta que el pist n esta en su carrera de compresi n y d jelo en esta posici n Esto cierra las v l...

Page 21: ...RIO FINAL EST AUTORIZADO PARA USAR ESTA INFORMACI N COMO BASE PARAEFECTUAR POR S MISMO CUALQUIER REEMPLAZO DE PARTES O REPARACI N AL PRODUCTO EN PRINCIPIO EL FABRICANTE CONSIDERA AL COMPRADOR Y O USUA...

Page 22: ...ESPECIFICACIONES SUJETAS A CAMBIO SIN PREVIO AVISO 22 EXPLOSIVO GENERAL...

Page 23: ...temente Repita este procedimiento si es necesario Llene el tanque de 25Lcon gasolina sin plomo limpia y nueva de 85 octanos o superior Use un embudo para este proceso Se recomienda no exceder la canti...

Page 24: ...Call 888 ready 19 888 73239 19 Nationwide Service Centers Manufactured under specs of 9163 Siempre Viva Road San Diego CA 92154 www valsi net Manufactured in Mexico...

Reviews: