DSBA3400 • Rév. 09/06/2020
48
EN
VR technical specifications
1)
The actuator tolerates voltage fluctuation of the electrical grid up to ± 10 % of its nominal system operating voltage
2)
The actuator tolerates temporary overvoltages of the electrical grid.
VR25 VR45
VR75
Installation
IP protection (EN60529)
IP68 (5 m 72 h)
Corrosion resistance (outdoor and
indoor use)
Housing: Alu EPOXY paint / cover: PA6 UL 94 V-0 or Alu EPOXY
paint
Drive : Steel + Zn treatment / Axles and screws : Stainless steel
Temperature
-20 °C à +70 °C (BBPR/GPS/GFS : -10 °C à +40 °C)
Hygrometry
maximum relative humidity 80 % for temperatures up to 31 °C decreasing linearly
to 50 % relative humidity at 40 °C
Pollution degree
Applicable POLLUTION DEGREE of the intended environment is 2 (in most cases).
Altitude
altitude up to 2 000 m
Extended environmental conditions
Outdoor use and in WET LOCATION
Sound level
61 dB
Weight
3,1 kg to 3.5 Kg max (4 Kg to 4,4 kg with aluminium cover)
Mechanical specifications
Nominal torque
20 Nm
35 Nm
60 Nm
Maximum torque
25 Nm
45 Nm
75 Nm
Operating time (90°)
7 s (400 V : 10 s)
15 s (400 V : 10 s)
20 s (400 V : 15 s)
Drive ISO5211
Star 17 F05-F07
Rotation angle
90° (others on request)
Mechanical stops
90° or 180°
Manual override
External shaft
Direction of rotation
Anticlockwise to open
Electrical specifications
Voltage
1)
(standard)
100 V to 240 V AC 50/60 Hz and 100 V to 350 V DC
15 V to 30 V AC 50/60 Hz and 12 V to 48 V DC
3-phase 400 V 50/60 Hz
Overvoltage category
2)
TRANSIENT OVERVOLTAGES up to the levels of OVERVOLTAGE CATEGORY ll
TEMPORARY OVERVOLTAGES occurring on the MAINS supply.
Power consumption
45 W - (52 W for 400 V)
Insulation motor class
Class B 400V motors and class F for the others
Torque limiter
Electronical
Duty cycle (CEI34)
50%
Limit switches maximal voltage
4 to 250 V AC/DC
(Overvoltage category II)
Limit switches maximal current
1 mA to 5 A max
Anticondensation heaters
10 W
Inrush current
Circuit breaker type D, nominal current according the number of actuators (max. 4 actu-
ators) or use a inrush current limiter at the output of the circuit breaker.
Voltage
1)
(GP5 and GF3)
100 V to 240 V AC 50/60 Hz and 100 V to 350 V DC
15 V to 30 V AC 50/60 Hz and 12 V to 48 V DC
Voltage
1)
(GP6, GPS and GFS)
100 V to 240 V AC 50/60 Hz and 100 V to 350 V DC
24 V to 30 V AC 50/60 Hz and 24 V to 48 V DC