background image

www.valoya.com

+358 10 2350 300

Version 2019.1

Standards / Contact

16

Contact:

 Melkonkatu 26, 
 00210 Helsinki,

 Finland

 T

  +358 10 2350 300

 E

 [email protected]

 W

  www.valoya.com

Standards applied 

(where applicable)

:

 

EUROPE

EN60598-1:

 Luminaires. General requirements and tests.

EN60598-2-1:

 Luminaires. Part 2: Particular requirements. Section one – Fixed general purpose luminaires.

EN62031:

 LED modules for general lighting. Safety specifications.

EN 62493:

 Assessment of lighting equipment related to human exposure to electromagnetic fields.

EN55015:

 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment.

EN61547:

 Equipment for general lighting purposes. EMC immunity requirements.

EN61000-3-2:

 Electromagnetic compatibility - Limits - Limits for harmonic current emissions.

EN61000-3-3:

 Electromagnetic compatibility – Limits - Limits for Voltage Fluctuations and Flicker.

IEC EN 61000-4-2:

 Electromagnetic compatibility (EMC)- Part 4-2: Testing and measurement techniques - electrostatic discharge immunity test.

IEC EN 61000-4-3:

 Electromagnetic compatibility (EMC)- Part 4-3: Testing and measurement techniques - radiated, radio-frequency, electromagnetic 

field immunity test.

IEC EN 61000-4-4:

 Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test.

IEC EN 61000-4-5:

 Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test.

IEC EN 61000-4-6:

 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, 

induced by radio-frequency fields.

IEC EN 61000-4-8:

 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity 

test.

IEC EN 61000-4-11:

 Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and 

voltage variations immunity tests.

IEC 61347-2-13:

 Lamp controlgear. Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules.

IEC 61347-1:

 Lamp controlgear - Part 1: General and safety requirements.

IEC 62384:

 DC or AC supplied electronic control gear for LED modules. Performance requirements.

EN62471:

 Photobiological safety of lamps and lamp systems.

EN62560:

 Self-ballasted LED-lamps for general lighting services by voltage >50V - Safety specifications.

EN62776

: Double-capped LED lamps designed to retrofit linear fluorescent lamps - Safety specifications.

NORTH AMERICA

UL1598:

 Luminare safety.

UL8750:

 Light Emitting Diode (LED) equipment for use In lighting products.

UL2108:

 Standard for Low Voltage Lighting Systems.

UL 8800

: Outline of Investigation for Horticultural Lighting Equipment

CSA C22.2: #9.0:

 General Requirements for Luminaires.

CSA C22.2: #250.0.8:

 Safety for Light emitting diode (LED) equipment for lighting applications.

CSA C22.2 No. 250.13-14:

 Light Emitting Diode (LED) equipment for use in lighting products.

 Distributor list can be found at:

www.valoya.com/contact

2019.1

Valoya® is a registered trademark of Valoya Oy in the European Community, the USA and certain other countries. 

Due to our continuous program of product development, data is subject to change without notice.

Summary of Contents for LightDNA-8

Page 1: ...Version 2019 1 www valoya com 358 10 2350 300 LightDNA INSTALLATION GUIDE LightDNA 8...

Page 2: ...Personen und Sachsch den f hren SVENSKA AKTA Felaktig installation kan leda till skador p per soner och lampan ESPA OL PELIGRO Una instalaci n inadecuada puede provocar lesiones o da ar la l mpara NED...

Page 3: ...ection devices is strongly advised Type C MCB s Miniature Circuit Breakers RCD Residual Current Device ICL Inrush Current Limiter SPD Surge Protection Device 13 Do not high voltage test 14 Install LED...

Page 4: ...e notify the carrier immediately and ask them to note that the delivery was not delivered in good condition If the packaging shows no damage but the goods inside are either missing defective or show o...

Page 5: ...very Check and Inspection LightDNA 8 luminaire Hangers LED Driver Power unit Chain Included carabiners ordered separately LightDNA PC Router Switch Ethernet Switch Option 1 8 way Ethernet Switch Optio...

Page 6: ...mm in 175 6 9 DC cable mm in 3000 118 LED DRIVER POWER UNIT A Length mm in 250 9 8 B Width mm in 90 3 5 C Height mm in 44 1 7 D AC cable 300 11 8 E DC cable 300 11 8 180 mm 7 in 175 mm 6 9 in 340 mm 1...

Page 7: ...mains plug fitted No Physical Weight kg lb 5 8 12 8 LED driver kg lb 1 9 4 2 Optical Efficiency 380 820nm PPF Up to 1 3 mol W Light intensity decay Q90 L90 hours 36000 Typical use life Q70 L70 hours...

Page 8: ...a com 358 10 2350 300 Version 2019 1 Installation Guide 8 LUMINAIRE ORIENTATION min 10 cm Do not cover the cooling fans SUSPENDED INSTALLATION GRID INSTALLATION EXAMPLES Only install with LEDs facing...

Page 9: ...eth0 2 Connect the LED driver to the LightDNA 8 luminaire 3 Connect the LED driver Ethernet Router and LightDNA PC to the mains supply LED driver installed outside a growth chamber LED driver install...

Page 10: ...tDNA PC Ethernet Router Control PC LAN LED Driver LED Driver LED Driver LED Driver Connect the incoming internet cable to port eth0 of the used Router Internet Switch 2 Switch 1 LightDNA PC Ethernet R...

Page 11: ...net Switch LightDNA PC Ethernet Router Switch LightDNA PC Ethernet Router Ethernet Router Control PC LAN LAN LED Driver LED Driver Group Network 1 Group Network 2 SOFTWARE Please view the document Lig...

Page 12: ...teristics site wiring impedance and the angle of the AC mainscycle at the specific moment power is applied Nuisance tripping issues may be improved by Reducing the quantity of LED drivers connected to...

Page 13: ...eaks above 4KV e g due to a lightning strike we recommend the installation of transient voltage surge suppression Do not apply power without the Neutral connected Ensure the supply is off before disco...

Page 14: ...10 2350 300 Version 2019 1 Care Maintenance 14 CLEANING Switch the supply OFF Allow to cool Do not use detergent Clean with a soft brush Wipe with soft clothes IP67 rated products Suitable for spray c...

Page 15: ...r Please be prepared to provide the following information about the issue Product model information e g B200 NS1 Product serial number plus YF or XF code Quantity showing problems Detailed problem des...

Page 16: ...ty EMC Part 4 6 Testing and measurement techniques Immunity to conducted disturbances induced by radio frequency fields IEC EN 61000 4 8 Electromagnetic compatibility EMC Part 4 8 Testing and measurem...

Reviews: