background image

Version 2019.1

www.valoya.com

+358 10 2350 300

Warnings and Explanations

3

RoHS 

PATENTS APPLY

IMPORTANT

Installation must be carried out by qualified persons, and according to the electrical safety rules & regulations applicable in 

your country!

1. 

Please read this manual thoroughly before use, and retain it for future reference.

2. 

Due to our continuous program of product development, data is subject to change without notice.

3. 

Unauthorized product tampering invalidates warranty & is a safety risk.

4. 

All electrical work must be carried out by qualified persons.

5. 

Always follow appropriate electrical codes.

6. 

Disconnect mains power before product installation, connection, or disconnection.

7. 

Products are fixed luminaires for indoor use (i.e. Install out of reach / Only movable using tools).

8.  LED-modules are non-replaceable light sources.
9. 

Do not use luminaires without LED Drivers (power units) connected (BX-, C-Series).

10. 

Connect LED drivers to electrical branch circuits (ensure suitable strain relief is fitted).

11. 

Products with an earth connection must be earthed for safety.

12.  Installation of additional electrical circuit protection devices is strongly advised:

• 

Type C MCB’s (Miniature Circuit Breakers).

• 

RCD (Residual Current Device).

• 

ICL (Inrush Current Limiter).

• 

SPD (Surge Protection Device).

13.  Do not high voltage test.
14. 

Install LED drivers against a flat surface to ensure optimal heat dissipation and lifetime (BX-, C-Series).

15. 

Do not connect products installed on different mains phases to the same dimming device (dimmable products only).

16. 

Observe published product temperature specifications and limits.

17.  Product surface temperature may become hot to the touch during use.
18.  Do not stare directly at any bright light source.
19. 

As a precaution, use suitable eye protection if working for long periods under high intensity lighting.

20. 

Dispose of all waste in accordance with local regulations.

21. 

The external flexible cable of the luminaire is only replaceable by Valoya.

22. 

For luminaries supplied with open-end supply cables:

a. Cables should not be concealed or extended through parts of the building structure.
b. Cables should not be located above a suspended/dropped ceiling, or permanently fixed to the building structure.
c. Cables must be visible over their full length, not strained, and protected from physical damage.
d. Cables must be used within 

their electrical ratings at the maximum temperature of the installed environment.

BEFORE YOU BEGIN

Summary of Contents for LightDNA-8

Page 1: ...Version 2019 1 www valoya com 358 10 2350 300 LightDNA INSTALLATION GUIDE LightDNA 8...

Page 2: ...Personen und Sachsch den f hren SVENSKA AKTA Felaktig installation kan leda till skador p per soner och lampan ESPA OL PELIGRO Una instalaci n inadecuada puede provocar lesiones o da ar la l mpara NED...

Page 3: ...ection devices is strongly advised Type C MCB s Miniature Circuit Breakers RCD Residual Current Device ICL Inrush Current Limiter SPD Surge Protection Device 13 Do not high voltage test 14 Install LED...

Page 4: ...e notify the carrier immediately and ask them to note that the delivery was not delivered in good condition If the packaging shows no damage but the goods inside are either missing defective or show o...

Page 5: ...very Check and Inspection LightDNA 8 luminaire Hangers LED Driver Power unit Chain Included carabiners ordered separately LightDNA PC Router Switch Ethernet Switch Option 1 8 way Ethernet Switch Optio...

Page 6: ...mm in 175 6 9 DC cable mm in 3000 118 LED DRIVER POWER UNIT A Length mm in 250 9 8 B Width mm in 90 3 5 C Height mm in 44 1 7 D AC cable 300 11 8 E DC cable 300 11 8 180 mm 7 in 175 mm 6 9 in 340 mm 1...

Page 7: ...mains plug fitted No Physical Weight kg lb 5 8 12 8 LED driver kg lb 1 9 4 2 Optical Efficiency 380 820nm PPF Up to 1 3 mol W Light intensity decay Q90 L90 hours 36000 Typical use life Q70 L70 hours...

Page 8: ...a com 358 10 2350 300 Version 2019 1 Installation Guide 8 LUMINAIRE ORIENTATION min 10 cm Do not cover the cooling fans SUSPENDED INSTALLATION GRID INSTALLATION EXAMPLES Only install with LEDs facing...

Page 9: ...eth0 2 Connect the LED driver to the LightDNA 8 luminaire 3 Connect the LED driver Ethernet Router and LightDNA PC to the mains supply LED driver installed outside a growth chamber LED driver install...

Page 10: ...tDNA PC Ethernet Router Control PC LAN LED Driver LED Driver LED Driver LED Driver Connect the incoming internet cable to port eth0 of the used Router Internet Switch 2 Switch 1 LightDNA PC Ethernet R...

Page 11: ...net Switch LightDNA PC Ethernet Router Switch LightDNA PC Ethernet Router Ethernet Router Control PC LAN LAN LED Driver LED Driver Group Network 1 Group Network 2 SOFTWARE Please view the document Lig...

Page 12: ...teristics site wiring impedance and the angle of the AC mainscycle at the specific moment power is applied Nuisance tripping issues may be improved by Reducing the quantity of LED drivers connected to...

Page 13: ...eaks above 4KV e g due to a lightning strike we recommend the installation of transient voltage surge suppression Do not apply power without the Neutral connected Ensure the supply is off before disco...

Page 14: ...10 2350 300 Version 2019 1 Care Maintenance 14 CLEANING Switch the supply OFF Allow to cool Do not use detergent Clean with a soft brush Wipe with soft clothes IP67 rated products Suitable for spray c...

Page 15: ...r Please be prepared to provide the following information about the issue Product model information e g B200 NS1 Product serial number plus YF or XF code Quantity showing problems Detailed problem des...

Page 16: ...ty EMC Part 4 6 Testing and measurement techniques Immunity to conducted disturbances induced by radio frequency fields IEC EN 61000 4 8 Electromagnetic compatibility EMC Part 4 8 Testing and measurem...

Reviews: