32
Operation Check & Aeration Settings Adjustment
Operation Check
Turn the
fi
replace
fl
ame up and down using the
remote control to con
fi
rm that the full range of inputs
is achieved—see the remote control operation
instructions on pages 37–41.
Aeration Settings
Light the
fi
re and allow the unit to warm up for 10–15
minutes to evaluate the
fl
ame picture. Burners are
equipped with an adjustable shutter to control primary
aeration. See the
fi
gures below. The shutter is
factory-set to an aeration gap which will give optimum
performance for the vast majority of installations.
In a few unusual installations, the
fl
ame picture may
be improved by adjusting the aeration. The need for
adjustment should be determined only by operating the
appliance with the ceramic rocks and window installed.
Increasing aeration
will cause the
fl
ames to appear
more transparent and blue showing more ceramic rock
glow.
Decreasing aeration
will cause the
fl
ames to appear
more yellow or orange showing less ceramic rock glow.
Too little aeration may result in black carbon
forming and dropping into the fi rebox.
Air Shutter
Remote Control Handset Wall Holder Installation
The remote control kit for this
fi
replace comes
complete with a wall-mounted holder. This
holder is not required in all installations but
is provided as an optional feature for those
customers who wish to mount the remote
handset to the wall.
To install the holder to the wall,
fi
nd a
convenient location and use the hardware
provided with the kit. See the diagram below for
required hardware and con
fi
gurations. Note that
the holder can be installed at the base of a light
switch plate.
IMPORTANT
. The location of the remote
control handset is important to assure proper
temperature regulation. To obtain a constant temperature, we recommend that the handset
should be between 3 and 15 feet away from the appliance
but not directly above it
. We also
advise that the handset should be located away from any other heat source and not in direct
sunlight as this may affect the temperature sensor located in the remote handset.
Packing Contents:
1 Wall Bracket A
2 Screws B
1 Screw C
2 Wall Anchor D
1 Spacer E
(detach before assembly)
1 Wall Bracket F
Switch Plate
Alternative 1
Alternative 2
Alternative 3
Open
Open
Close
Close
NG
Flashback
shield (for
LPG only)
LPG Air Shutter
Slider
Open
Close
LPG
NG Air Shutter
Slider & Cover
INSTALLATION