Page 18
INSTALLER GUIDE
5.
There is a length of self
adhesive foam seal supplied with
the fire. This will need to be fitted
to the outer rear edges of the side
and top flanges of the convector
box. Cut the foam seal to the
required length. Be careful not to
stretch the seal when measuring.
Remove the protective backing
from the foam seal and fit this to
the rear of the top flange (See
figure 11).
8.2 The Flue Restrictor
This appliance is supplied with a
flue restrictor for use where the
flue draught is excessive.
The restrictor must
not be fitted where a precast flue or a 125mm
flue liner is used
. For flue liners greater than
125mm and all other installations the restrictor
should be fitted. There may however, be certain
exceptional circumstances where fitting the
restrictor causes the fire to fail the spillage test.
In such cases the restrictor will have to be
removed. After removal conduct the spillage
check again.
Fit the restrictor as shown in figure 12 using the two screws provided.
Figure 12. Fixing restrictor
Figure 11. Fitting the foam seal