25
QUALIFIED
INSTALLER
20”
43”
46”
1/2” thick non-combustible
cement board required above,
on each side and below
engine opening (NOT supplied)
NOTE: Height of cavity may be
affected by vent configuration
- see page 26
Between underside
of header and bottom
of firebox
No hearth required.
If using a hearth,
see page 22.
NOTE: This unit requires a
solid platform to support it.
Combustible framing allowed
beneath fireplace. When the
appliance is installed directly
on carpeting, tile or other
combustible material other
than wood flooring, the
appliance shall be installed
on a metal or wood panel
extending the full width
and recessed depth of the
appliance
NON-COMBUSTIBLE MATERIALS ONLY
READ INSTRUCTIONS
MATÉRIAUX INCOMBUSTIBLES SEULEMENT
CONSULTEZ LE GUIDE D’INSTALLATION
NON COM
NON-COMBUSTIBL
BUSTIBLE MATER
E MATER
IALS ON
IALS ONLY
LY
READ INSTRUCTIONS
READ INSTRUCTIONS
MATÉRIAUX INCOMBUSTIBLES SEULEMENT
CONSULT
CONSULT
EZ LE G
EZ LE G
UIDE D’
UIDE D’
INSTALL
INSTALLATION
ATION
Min. 48” (1219 mm)
40” (1016 mm)
M
in. 44-1/2”
(1130 mm)
M
in.
20-1/2”
(521 mm)
14-3/4”
(375 mm)
M
in.
9-1/4”
(235 mm)
Min. 4”
(102 mm)
Min. 4”
(102 mm)
Flush with bottom of unit;
add extra cement board
if overlapping framing.
Minimum coverage area of non-combustible cement board.
Any
wall
finish applied to shaded area must be non-combustible.
Linear 1500 fireplace outline
(including stand-offs)
Non-combustible
cement board
required
thickness:
1/2 inch (13 mm)
NON-COMBUSTIBLE MATERIALS ONLY
READ INSTRUCTIONS
MATÉRIAUX INCOMBUSTIBLES SEULEMENT
CONSULTEZ LE GUIDE D’INSTALLATION
23.
27.
Framing Requirements
Framing Dimensions
Minimum Cement Board Dimensions
Note: If using
optional LDK
HeatShift Duct
Kit, refer to LDK
instructions packed
with kits as framing
is aff ected.