background image

4005426-10

©2018, Miles Industries Ltd.

This appliance may be installed in an after-
market permanently located, manufactured 
(mobile) home where not prohibited by local 
codes.
This appliance is only for use with the type 
of gas indicated on the rating plate. This 
appliance is not convertible for use with 
other gases, unless a certifi ed kit is used.

HOT GLASS

 WILL 

CAUSE BURNS.

DO NOT TOUCH 

GLASS 

UNTIL COOLED.

NEVER 

ALLOW CHILDREN 

TO TOUCH GLASS.

DANGER

!

A barrier designed to reduce the risk of burns from the hot 
viewing glass is provided with this appliance and shall be 
installed for the protection of children and other at-risk 
individuals.

Ce guide est disponible en français sur demande.

This appliance is a domestic room-heating 
appliance. It must not be used for any other 
purposes such as drying clothes, etc.

This appliance is suitable for installation in 
a bedroom or bed sitting room.

INSTALLER

Leave this manual 
with the appliance.

CONSUMER

Retain this manual 
for future reference.

Please read this manual 

BEFORE 

installing and 

operating this appliance.

INSTALLATION & OWNER’S MANUAL

— Do not store or use gasoline or other 

fl ammable vapors and liquids in the 
vicinity of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS

 

▪ Do not try to light any appliance.

 

▪ Do not touch any electrical switch; do 

not use any phone in your building.

 

▪ Leave the building immediately.

 

▪ Immediately call your gas supplier from 

a neighbor’s phone. Follow the gas 
supplier’s instructions.

 

▪ If you cannot reach your gas supplier, 

call the fi re department.

— Installation and service must be 

performed by a qualifi ed installer, 
service agency or the gas supplier.

  

!

  WARNING

FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly 
could result in serious injury, death, or 
property damage.

Direct Vent Zero Clearance Gas Fireplaces
1500JN (natural gas) & 1500JP (propane gas)

This manual contains instructions to install the

 

ENGINE ONLY. 

A trim kit is

 REQUIRED 

to 

complete the installation. A barrier screen is 
provided with the trim kit. 

Refer to the manual 

supplied with the trim for installation.

L1 Series

Summary of Contents for L1 Series

Page 1: ...ONSUMER Retain this manual for future reference Please read this manual BEFORE installing and operating this appliance INSTALLATION OWNER S MANUAL Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave...

Page 2: ...tently 7 Using the Remote Control 8 Using the Wall Switch 13 Kits Accessories 13 Lighting Instructions 14 Maintaining Your Fireplace 15 Servicing Your Fireplace 15 Annual Inspection 15 Cleaning Your Fireplace 16 Checking Pilot and Burner Flames 18 Replacing Batteries 19 Using Handset Wall Holder 19 Warranty 65 Specifications 20 Overview 21 Dimensions Location 22 Mantel Hearth Clearances 23 Framing ...

Page 3: ...re and draperies Clothing or flammable material should not be placed on or near the appliance This unit must be used with a vent system as de scribed in this installation manual No other vent sys tem or components may be used This gas fireplace and vent assembly must be vented directly to the outside and must never be attached to a chimney serving a separate solid fuel burning appli ance Each gas ap...

Page 4: ...risk individuals in the house Install an approved after market safety gate to keep toddlers young children and other at risk individuals a safe distance from the fireplace Keep the remote control handset out of reach of children at all times A wall mount storage holster is provided with your remote control handset Ensure that the fireplace including the pilot light is completely turned off when child...

Page 5: ...larly the glass window Do not let children touch the glass or any parts of your fireplace even after it is turned off as it is still hot Use the barrier screen provided with the trim or a gate to reduce the risk of severe burns Keep the remote control handset out of reach of children Hot wall surfaces The wall directly above the fireplace is very hot when the fireplace heats It is constructed of non c...

Page 6: ...f this manual Introduction Thank You For purchasing a Valor by Miles Industries Your new radiant gas heater is a technical appliance that must be installed by a qualified dealer Each Valor fireplace is fully tested during the production process for your safety and comfort Your unit has been professionally installed by Dealer Name ________________________________ Phone Number ________________________...

Page 7: ... signal from the remote control In the unlikely event that you cannot turn off your fireplace with the remote control handset use the wall switch if the wall switch malfunctions and will not turn off the fireplace wait 6 hours and the fireplace will automatically go to pilot You can then access the controls inside your fireplace Alternately turn off gas supply In all cases call your dealer for service as...

Page 8: ...s and settings 2 returns to set mode turns the burner and the pilot off Large flame button flames up sets hours temperature Small flame button flames down and off sets minutes temperature Current temperature F or C Current time 12 or 24 hour clock Modes Manual Temperature Timer Handset sensor Battery status Current programmed period Timer Period start or end Temp Timer KHQ WKH SLORW LV Rႇ LW ZLOO ...

Page 9: ...R 0 1 PRGH RXEOH FOLFN ODUJH À DPH EXWWRQ ODPH DXWRPDWLFDOO JRHV WR KLJK UH ZLOO EH GLVSOD HG 0DQXDO 0RGH 0DQXDO ODPH HLJKW GMXVWPHQW SUHVV RZ DQG LJK LUH D WLPH 7HPSHUDWXUH 0RGH SSOLDQFH PXVW EH LQ VWDQGE PRGH SLORW LJQLWHG 7KH URRP WHPSHUDWXUH LV PHDVXUHG DQG FRPSDUHG WR WKH VHW WHPSHUDWXUH 7KH À DPH KHLJKW LV WKHQ DXWRPDWLFDOO DGMXVWHG WR DFKLHYH WKH D WLPH 6HW 7HPSHUDWXUH x 2 x 2 MAN TEMP ULHÀ...

Page 10: ... 3UHVV 2 RU VLPSO ZDLW WR FRPSOHWH SURJUDPPLQJ 6 77 1 7 7 0 7 03 5 785 6 77 1 7 1 77 0 6 7 7 03 5 785 HIDXOW 6HWWLQJV VXQ HIDXOW 6HWWLQJV PRRQ 2 3UHVV ODUJH À DPH EXWWRQ WR LQFUHDVH 1LJKWWLPH 6HWEDFN 7HPSHUDWXUH 3UHVV VPDOO À DPH EXWWRQ WR GHFUHDVH 1LJKWWLPH 6HWEDFN 7HPSHUDWXUH 3UHVV 2 RU VLPSO ZDLW WR FRPSOHWH SURJUDPPLQJ ULHÀ SUHVV 6 7 EXWWRQ WR VFUROO WR 7 03 PRRQ PRGH ROG WKH 6 7 EXWWRQ XQWLO ...

Page 11: ... 7 0 5 PRRQ ZKLOH WKH WLPH À DVKHV 3UHVV ODUJH À DPH EXWWRQ WR VHW WKH KRXU 3UHVV ODUJH À DPH EXWWRQ WR VHW WKH KRXU 3UHVV VPDOO À DPH EXWWRQ WR VHW WKH PLQXWHV 3UHVV VPDOO À DPH EXWWRQ WR VHW WKH PLQXWHV 6 77 1 3 21 7 0 6 77 1 3 21 7 0 ULHÀ SUHVV 6 7 WR VFUROO WR 7 0 5 PRGH VXQ ZKLOH WKH WLPH À DVKHV ROORZ WKH LQVWUXFWLRQV JLYHQ WR VHW 3 21 WLPH 6 77 1 3 2 7 0 ULHÀ SUHVV 6 7 WR VFUROO WR 7 0 5 PR...

Page 12: ...GH 7KH YDOYH ZLOO WXUQ WR SLORW À DPH LI WKHUH LV QR FKDQJH LQ À DPH KHLJKW IRU D KRXU SHULRG Q 7HPSHUDWXUH 7LPHU 0RGH LI WKH DPELHQW URRP WHPSHUDWXUH FKDQJHV WKH À DPH KHLJKW ZLOO DGMXVW DXWRPDWLFDOO WR PDLQWDLQ VHW WHPSHUDWXUH DQG WKH UH ZLOO FRQWLQXH WR IXQFWLRQ QRUPDOO 7KH YDOYH ZLOO WXUQ WR SLORW À DPH LI WKH VHW WHPSHUDWXUH DQG WKH DPELHQW URRP WHPSHUDWXUH UHPDLQ WKH VDPH RYHU D KRXU SHULRG ...

Page 13: ...1565LLK Linear Lighting Kit 1595CFK Circulating Fan Kit 1270RBK Remote Blower Kit LDK HeatShift Duct Kits gravity flow Hearth Gate Hearth gates such as Cardinal s VersaGates are available at retail stores carrying safety products for children Required Kits Information accurate at the time of printing and subject to change without notice Optional Accessories Information accurate at the time of print...

Page 14: ...or gas including near the floor If you smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 3 AUTOMATIC IGNITION MAN knob 2 in ON position Ensure Flame Adjustment knob 3 is set to lowest setting Fig 1 Locate the pilot Fig 3 inside of firebox at left hand side On the remote control handset press the OFF button red dot and large flame button s...

Page 15: ...spect the operation of the flame safety system Pilot or Flame rectification device 4 Inspect and ensure the lighting of the main burner occurs within 4 seconds of the main gas valve opening Visual inspection should match that outlined in the appliance instruction manual Inspect primary air openings for blockage See Checking Pilot and Burner Flame section of this manual 5 Inspect condition of vent an...

Page 16: ...ed Use a soft damp cloth to apply the cleaner Dry the glass with a soft dry preferably cotton cloth Most paper towels and synthetic materials are abrasive to ceramic glass and should be avoided Our dealers have had good results from the products listed below We cannot however guarantee the results of these products Brasso Polish Plus by Kelkem Cook Top Clean Creme by Elco White Off by Rutland Turtl...

Page 17: ...hat the screen is properly hooked to the trim and secure 1 2 3 WARNING Failure to install the window correctly can leak carbon monoxide affect the performance of the fireplace damage components cause overheating resulting in dangerous conditions Damage caused by incorrect window installa tion is not covered by the Valor warranty DANGER The window unit must be correctly installed fastened and sealed ...

Page 18: ...t and burner flames should be made Check after the fire has been on for at least 30 minutes The pilot flame must cover the tip of the thermocouple probe The main burner flame pattern will vary from appliance to appliance depending on the type of installation and climatic conditions The appliance area must always be kept clear and free from combustible materials gasoline and other flammable vapors and l...

Page 19: ... seasons depending on usage Removing the batteries in the off season will extend the battery life To replace the batteries The battery compartment is located next to the wall switch in the vicinity of the fireplace Its front plate is attached with magnets to the wall switch box 1 Pull on the plate next to the wall switch to access the batteries 2 Disconnect the snap connector from the battery holder...

Page 20: ...with natural gas Heater engine 1500JP is used with propane gas The supply pressure must be between the limits shown in the Ratings section above The supply connection is 3 8 NPT male and located on the left hand side of the firebox A shut off valve not supplied is required on the supply line to isolate the unit during service See Gas Supply Installation section for details Conversion Kits The 1500 L...

Page 21: ... ge 23 Combustible Framing Allowed Beneath Fireplace When the appliance is installed directly on carpeting tile or other combustible material other than wood flooring the appliance shall be installed on a metal or wood panel extending the full width and recessed depth of the appliance Remote Battery and Wall Switch Kit required 35 foot wire length supplied Overview WARNING Some materials or items a...

Page 22: ...rance Stand Offs eader He Center Line 6 5 8 dia Venting field convertible from top to rear outlet Center of vent Heat shield required for rear vent outlet applications 3 3 4 95 mm 4 102 mm 32 3 8 822 mm 33 1 8 841 mm 14 1 2 2 2 369 m mm m 9 3 8 238 m mm 46 1168 mm 42 1067 mm 39 11 16 1009 mm Zero Clearance to Stand offs at Back and Sides Zero Clearance at back corners Ze ero Clearance at a back co...

Page 23: ...el Projection from Face of Cement Board Mantel Height from Bottom of Unit Fireplace Opening Ceiling 24 Min to Ceiling 44 42 40 38 33 23 7 8 9 3 8 4 minimum to combustible or non combustible hearth Mantel Hearth Clearances Combustible Mantel Left Side View Note Use of the optional LDK HeatShift Duct Kits affects mantel and hearth clearances See instructions packed with LDK kits ...

Page 24: ...24 QUALIFIED INSTALLER 39 11 16 Fireplace Opening Wall Min 4 to wall or combustible mantel leg Face of Finished Wall FIREPLACE Combustible Sidewall Mantel Leg Top View Mantel Hearth Clearances ...

Page 25: ...NSTALLATION NON COM NON COMBUSTIBL BUSTIBLE MATER E MATERIALS ON IALS ONLY LY READ INSTRUCTIONS READ INSTRUCTIONS MATÉRIAUX INCOMBUSTIBLES SEULEMENT CONSULT CONSULTEZ LE G EZ LE GUIDE D UIDE D INSTALL INSTALLATION ATION Min 48 1219 mm 40 1016 mm Min 44 1 2 1130 mm Min 20 1 2 521 mm 14 3 4 375 mm Min 9 1 4 235 mm Min 4 102 mm Min 4 102 mm Flush with bottom of unit add extra cement board if overlapp...

Page 26: ...rtical vent pipe Approx 10 3 4 274 mm from back surface of wall finish to front surface of appliance case w no vent offset 15 1 16 383 mm 14 1 2 369 mm 9 3 8 238 mm 19 1 4 489 mm Fireplace Opening PARTIAL SHELF top outlet 1 2 thick non combustible Cement Board Framing with Partial Shelf Top Outlet Framing Requirements ...

Page 27: ...than 12 305 mm vertical pipe is used otherwise elbow requires 3 77 mm top clearance Approx 10 3 4 274 mm from back surface of wall finish to front surface of appliance case w no vent offset 15 1 16 383 mm 14 1 2 369 mm 9 3 8 238 mm 19 1 4 489 mm Fireplace Opening PARTIAL SHELF top outlet 1 2 thick non combustible Cement Board Framing with Partial Shelf Top Outlet vent elbow in cavity Framing Requi...

Page 28: ... surface of appliance case For venting clearances see Venting Chart section 43 1093 mm to underside of combustible cavity 14 1 2 369 mm 9 3 8 238 mm 19 1 4 489 mm Fireplace opening FULL SHELF rear outlet 1 2 thick non combustible Cement board Framing with Full Shelf Rear Outlet Framing Requirements ...

Page 29: ...stible wall assembly up to 8 inches in thickness A non combustible wall can be of any thickness up to the maximum horizontal run of vent pipe allowed for the particular installation Framing Vent in Combustible Walls Ceilings When penetrating through combustible walls and ceilings frame a minimum of 10 in x 10 in opening and ensure that the insulation is kept clear of the vent pipe using either a w...

Page 30: ...IZONTAL TERMINATION 2 PIECE WALL THIMBLE PIPE LENGTH PIPE LENGTH PIPE LENGTH PIPE LENGTH 90 ELBOW CEILING FIRESTOP ATTIC FIRESTOP ATTIC INSULATION SHIELD FLASHING STORM COLLAR VERTICAL TERMINATION Co axial Venting Typical Co axial Venting Components Rear Outlet Top Outlet Top Outlet ...

Page 31: ... as long as they are within the allowable limits shown on the chart below 4 A maximum of 4 x 90 degrees elbows or equivalent 2 x 45 degrees 90 degrees can be used Excludes the 45 degrees take off elbow shipped with the appliance 5 Each 90 degrees elbow installed on the horizontal plane is equivalent to a 3 feet horizontal pipe therefore 3 feet must be subtracted from allowable horizontal run 45 deg...

Page 32: ... rear venting with no vertical rise The level of restriction required depends on the vertical rise in the venting system and to a lesser degree the horizontal run and number of elbows The amount of restriction is based on laboratory tests The ideal restrictor position may vary slightly especially when the vent pipe length is near the limits of the acceptable configurations for each type of restrict...

Page 33: ...embly located within 15 feet 4 6 m below the terminal 36 90 I Clearance to service regulator vent outlet 36 90 J Clearance to non mechanical air supply inlet to the building or the combustion air inlet to any other appliance 12 30 K Clearance to a mechanical air supply inlet 72 180 L Clearance above paved sidewalk or a paved driveway located on public property Note A vent must not terminate direct...

Page 34: ...0 12 2 5 Over 10 12 to 11 12 3 25 Over 11 12 to 12 12 4 Over 12 12 to 14 12 5 Overhang should not extend beyond vent if within 48 of termination cap Horizontal overhang Vertical wall Min 24 unvented soffit Min 36 vented soffit Termination cap Min 18 Storm collar Roof flashing H Vertical Vent Termination Co axial Venting ...

Page 35: ...Axial to Co Linear appliance Adapter 1156CLA two lengths of 2 ply 3 dia flexible chimney liner approved for venting gas appliances a co linear termination kit and flashing or a co linear to co axial adapter and either a high wind vertical vent terminal cap or a low profile vertical termination Firebox zero clearance standoffs supplied with the heater are not required for this application Rules for Co ...

Page 36: ...verlapping framing 40 1016 mm Min 48 1219 mm 1 4 235 m m Possible screw loc in the designated ard flush with bo of heater add extra overlapping framing Wider trim 1550 can adjust up to 1 forward of surface of cement board Narrow trim 1575 can adjust up to 5 8 forward of surface of cement board Plan Wall Finish Non Combustible Materials Specifications Material which will not ignite and burn Such mat...

Page 37: ...before finishing the wall Cement board has the ability to absorb up to 30 percent of its weight in water and may shrink as much as 1 8 over a 48 length when drying from a saturated condition Running the fireplace before final finishing will help drive out moisture Always pre drill screw holes through cement board and use screws with self milling head Always use tape over joints Behind joints double up...

Page 38: ...hield Swivel the outlet so that it is oriented towards the rear and reinstall to heater 6 screws Reinstall heat shield to top of appliance 3 screws Rear outlet with required heat shield Convert from Top to Rear Outlet if required This unit is supplied with a top vent outlet which can be field converted to a rear vent outlet Please note that the rear outlet requires the instal lation of the heat shi...

Page 39: ...bottom railing and set it aside in a safe place to avoid damage Installation Fit Appliance into Framing 1 Remove the 4 screws retaining the engine to its pallet 2 Taking great care not to cut your hands on the sheet metal edges lift the appliance out of its packing base and place it in the framing Make sure that the unit is at the right height with consideration to the height of the hearth or comb...

Page 40: ...ll be required and the duplex receptacle will need to be split to ensure separate control of fan and lighting The duplex receptacle and box must be located as per these instructions Wiring within this box must have a minimum 90 C temperature rating Installation 1 Thread the cable through the cable clamp and through the hole in the lower right hand corner of the fireplace casing Do not tighten the c...

Page 41: ...e disconnected for service An individual shut off valve not supplied is required on the supply line ahead of the flex connector Use only new black iron or steel pipes or copper tubing if acceptable check local codes Note that in USA copper tubing must be internally tinned for protection against sulfur compounds Unions in gas lines should be of ground joint type The gas supply line must be sized and ...

Page 42: ...ng pressure testing may result in regulator or valve damages and void the warranty Consult your dealer in case of damages Pressure Test Points The minimum supply pressure is given in the section Specifications of this manual page 20 All piping and connections must be tested for leaks af ter installation or servicing All leaks must be corrected immediately When testing for leaks Make sure that the ...

Page 43: ...of the rear of the firebox The panel sits on the ledge behind the tabs 4 Place the left panel against the left wall of the firebox 5 Place the right panel against the right wall of the firebox 6 Tighten the side panel anchors on each side of the firebox 7 Insert the top panel over the top of one of the side panels as far as possible The bevel goes on the top and straight edge fire side Rotate the other...

Page 44: ...Push the platform as far back as possible to maximize the air gap behind the burner 2 Fill a small container with the equivalent of approximately 3 cups 750 ml of vermiculite from the bag supplied 3 Carefully spread the vermiculite on the surface of burner patting it gently with your hand to form a single layer to the approximate level of the top of the flange at the edge of the burner Do not pour ...

Page 45: ...the left peg of this log Place the log s left peg in the front hole for natural gas fire Place the log s left peg in the rear hole for propane gas fire 2 Place the rear left log as indicated Propane Propane gas gas Natural gas Natural gas 3 Place the rear right log as indicated 4 Place the front left log as indicated 5 Place one end of the cross log on the rear center log as indicated and rest its o...

Page 46: ...ner to distribute fireglass not included Decorative Glass Murano Glass kit which contains 1 bag of clear 1 2 fireglass 1 glass platform Installation Carefully unpack the kit 1 Install the steel platform around the burner as indicated The openings in the platform should be underneath The edge of the burner protrudes above the platform Push the platform as far back as possible to maximize the air gap ...

Page 47: ... the glass platform as far back as possible to maximize the air gap behind the burner 3 Fill a small container with approximately 3 cups 750 ml of fireglass 4 Carefully spread the fireglass on the surface of burner patting it gently with your hand to form a single layer to the approximate level of the top edge of the flange around the burner Do not pour too much to avoid blocking the burner ports 5 S...

Page 48: ...rner to the right to disengage it from the orifice and lift it out of the firebox 3 Remove the two platform supports 2 screws each flip them upside down and secure them back with the same screws 4 Re install the burner locating its left end within the burner support and sliding the burner to the left while centering it onto the injector elbow Fix the burner support screw at the right end of burner to...

Page 49: ...shield Pilot shield Fireglass installed top view 7 Carefully spread the fireglass in the tray and on the burner Do not overfill the burner to avoid blocking the burner ports Ideally one layer of fireglass on the burner is sufficient NOTE Ensure the area around the pilot shield is not piled too high with fireglass and also ensure the area within the pilot shield is clear of fireglass Installation ...

Page 50: ...ks Shale Twigs 1 Place three rocks on the burner one at each end and one in the middle as indicated The rocks should not sit on top of the burner ports but can overhang slightly Note Although these rocks can be installed after the shale is distributed it is recommended to install them first to obtain a better flame display Installed platform Gap behind burner No gap in front of burner Top view platf...

Page 51: ...s may overhang slightly over the burner edge 4 Add the twigs to the rocks placing them as shown Note The position of the twigs are specific to obtain the best flame pattern Note The acceptable variations are only for rocks installed on the black platform outside of the shale bed or pilot shield Do not put any rock on the pilot shield Do not put more rocks on the shale bed than what is shown below Pi...

Page 52: ...lation Platform Carefully unpack the kit Install the steel platform around the burner as indicated The openings in the platform should be underneath Push the platform as far back as possible to maximize the air gap behind the burner Logs embers splinters Some logs are marked with a number to facilitate the installation Some logs also have positioning pins underneath which fit into the SQUARE holes ...

Page 53: ... overlaps slightly the pilot shield Log 2 rests on notch of log 1 Log 3 s narrow end rests on the pilot shield Log 4 straddles the burner rest it over the smaller burner ports Log 7 rests on front notch of log 4 Log 9 straddles the burner rest it over the smaller burner ports Log 8 rests on the notch of log 9 Log 11 rests on notch of log 10 1 2 3 4 7 8 9 10 11 1 2 3 4 7 8 4 7 8 9 10 11 ...

Page 54: ... Valor fireplace The use of any other products may void your fireplace warranty 2 Carefully spread the embers in a single layer on the surface of burner between the logs Do not pile up the embers to avoid blocking the burner ports 3 Some embers may be added on the platform to cover the edge of the burner and the round holes 4 Spread some splinters to the embers Pilot shield NOTE Ensure the area with...

Page 55: ...ass and the frame as indicated Hot Glass Warning Plate WARNING Failure to install the window correctly can leak carbon monoxide affect the performance of the fireplace damage components cause overheating resulting in dangerous conditions Damage caused by incorrect window installa tion is not covered by the Valor warranty DANGER The window unit must be correctly installed fastened and sealed after se...

Page 56: ...nel It is maintained in position with Velcro bands 1 Pull out the receiver from its location to connect the battery holder and wall switch 2 Feed the white connector end of the harness assembly through side holes in fireplace liner body to receiver Ensure sufficient harness length to allow for removal of receiver Note coil up any extra harness at fireplace end 3 Connect switch to auxillary 5 pin junct...

Page 57: ...gh the 2 side slots of battery cover assembly 12 Position battery holder to rear face and secure together with cable tie note clearance is required for battery snap connection 13 Make the snap connection load 4 AA alkaline batteries into holder included with fireplace then feed back into junction box assembly Note Do not put batteries in the receiver only in the battery holder by the wall switch 14...

Page 58: ...a 15 minute warm up Increasing aeration will cause the flames to appear more transparent and blue showing more ceramic effects glow Decreasing aeration will cause the flames to appear more yellow or orange showing less ceramic effects glow Too little aeration may result in black carbon forming and dropping into the firebox To access the air shutter remove the front middle platform as indicated The air...

Page 59: ...wall mounted holder This holder is not required in all installations but is provided as an optional feature for those customers who wish to mount the remote handset to the wall To install the holder to the wall find a convenient location and use the hardware provided with the kit See the diagram below for required hardware and configurations Note that the holder can be installed at the base of a lig...

Page 60: ...60 QUALIFIED INSTALLER Wiring Diagram Wall Switch Kit GV60 Wiring Diagram Remote Battery Holder 4 AA Batteries 5 pin connector 9 Volt connector ...

Page 61: ...O 5LVH 9 61 7 67 70 67 6 9HQW GDSWHUV RXSOHUV 8QLYHUVDO GDSWHU OH RXSOHU 70 R OLQHDU OH RQQHFWRU 9 R D LDO WR R OLQHDU GDSWHU 9 70 R OLQHDU WR R D LDO GDSWHU 9 70 7 7 9 WR 9HQW GDSWHU 9 9 OXPLQXP OH LEOH LQHU RU GLDPHWHU 127 SO OLQHU DSSURYHG WR 1 8 6 VXLWDEOH IRU YHQWLQJ JDV DSSOLDQFHV V PDQXIDFWXUHG E OH OH PDVWHUV RU RWKHUV 6HULHV GMXVWDEOH 3LSH HQJWK DQG 3LSH WHQVLRQV DOYDQL HG RU ODFN 9 9 WR ...

Page 62: ...HGUDO HLOLQJ 6XSSRUW 9 6 7 6 56 7 HLOLQJ LUHVWRS ORRU 6XSSRUW 9 6 7 6 70 6 69 63 69 6 WWLF 5DGLDWLRQ 6KLHOG LUHVWRS 70 6 6 6 DOO 6WUDS 9 6 7 6 70 6 6 9LQ O 6LGLQJ 6WDQGRႇ 9 966 7 96 70 966 69 96 96 6 OERZ 6WUDS 2ႇ VHW 6XSSRUW 9 6 7 26 70 26 7HUPLQDO XDUG 9 7 6 5 7 1RWHV ROORZ LQVWUXFWLRQV VXSSOLHG ZLWK HDFK PDQXIDFWXUHU V FRPSRQHQWV 8QOHVV RWKHUZLVH VSHFL HG DOO WKH SDUWV DQG DVVHPEOLHV IURP WKH D...

Page 63: ...thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed 2 APPROVED CARBON MONOXIDE DETECTORS Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 3 SIGNAGE A metal or plastic identification plate shall be permanently mounted to the exterior of the building at...

Page 64: ...tions shall be included with the appliance or equipment installation instructions and 2 The special venting systems shall be Product Approved by the Board and the instructions for that system shall include a parts list and detailed installation instructions e A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment all venting instructions...

Page 65: ...i Improper installation operational or environmental conditions ii Inadequate ventilation in the area or competition for air from other household equipment or appliances iii Chemicals dampness condensation or sulphur in the fuel supply lines which exceeds industry standards i This warranty does not cover glass log breakage or damage to the unit while in transit j The Company does not allow anyone ...

Page 66: ...hutter natural gas 4002907 30b Anti flashback shield gas propane 4006503 31 Injector bracket 4002899 32 Burner gasket air shutter 4002906 Description Part Number 33 Gasket silicone 620C016 34 Pilot sealing plate 4002910 35 Burner module plate 4002775 36 Gaskets module plate long 2 3000400 37 Gaskets module plate short 2 3000399 38 Valve to elbow pipe assembly 4002904 39 Pipe s s flex 4000345 40 Ther...

Page 67: ...00DGS 74 Classic 1 2 clear fireglass 3 4004521 75 Fireglass tray 4003473BY 76 Middle platform brackets 2 4003033 77 Rocks Shale Set 1514RSS 78 LH twig 4001827 79 LH twig short 2 4001827S 80 RH twig 2 4001828 81 Grey Rock S4 A 6 4002338 82 Dark Grey Rock S4 A 4 4002339 Description Part Number 83 Grey Rock S4 B 4 4002340 84 Dark Grey Rock S4 B 6 4002341 85 No 7 Grey 5 Matte pitted rock 4002650 86 No ...

Page 68: ...Parts 51 51a 51b 51c 51d 51e 51f 51g 51h 51i 1 2 3 4 92 92 92 92 93 4 7 7 9 10 13 13a 11 8 56 54 53 55 14 18 12a 12b 52 15 16 19 20 24 25 26 28 27 17 29 30a 30b 31 32 33 35 36 37 34 41 38 39 40 6 6 5 48 50 47 49 46 44 43 42 45 107 ...

Page 69: ...ts 60 73 77 57 61 62 63 64 65 72 71 70 69 68 67 66 58 75 76 59 74 74 91 81 78 79 80 82 83 84 85 86 87 90 89 88 6 6 4 2 2 4 2 2 1514RSS 1500DGS 1505DWK 1500DGM 2 97 95 96 94 1500SWK 1 2 3 4 7 8 9 10 11 99 98 100 101 103 102 104 105 106 ...

Page 70: ...70 OWNER S INFORMATION ...

Page 71: ...vided will be used for customer records only Online Warranty registration at www valorfireplaces com Cut out page fill information and mail to Miles Industries Ltd Fireplace Information Model Number 1500 JN or JP INSTALLED OUTDOOR Serial Number Date Purchase yyyy mm dd Dealer Customer Information First Name Last Name Contact Information Email Mailing Address Address City Province State Postal Zip Co...

Page 72: ... Shut Thank you for choosing a Valor Product Postage needed Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC V7H 3B1 Canada Fold here Online Warranty registration at www valorfireplaces com ...