Approvals & codes
These appliances are certi
fi
ed by ANSI Z21.88-2007 / CSA 2.33-2007
Vented Gas Fireplace Heater
for use in Canada
and USA. These appliances are for installation directly venting through an outside wall or through the roof.
Model 534XAN is for use with natural gas.
Model 534XAP is for use with propane gas. It can be converted for use with natural gas with kit #607NGK.
These appliances comply with CGA P.4.1
Testing method for measuring annual fi replace effi ciencies
.
The installation must conform with local codes or, in the absence of local codes with the
National Fuel Gas Code, ANSI
Z223.1
or the
Natural Gas and Propane Installation Code CAN/CGA-B149
. Only quali
fi
ed licensed or trained personnel
should install these appliances.
These appliances, when installed, must be electrically grounded in accordance with local codes or, in the absence of local
codes, with the
National Electrical Code, ANSI/NFPA 70
or the
Canadian Electrical Code, CSA C22.1
.
*Tested to
CAN/CGA - 2.17 Gas fi red appliances for use at high altitudes
. In the USA, installations may require
deration over 2000’—check local codes.
Wall Thickness
The vent system (when horizontally terminated) is approved to pass through combustible wall construction of up to
14” (36 cm) thick.
A non-combustible wall can be any thickness up to the maximum horizontal run of vent pipe allowed for the
particular installation—see
Location
section.
Model
534XAN
534XAP
Gas
Natural
Propane
Altitude (Ft.)
0-4500 *
Input Max. (Btu/h)
24,000
24,000
Input Min. (Btu/h)
6,500
13,000
Manifold pressure (in w.c..)
3.8 – 4.2
9.3 – 9.7
Min. Supply pressure (in. w.c.)
5.0
11.0
Max. Supply pressure (in. w.c.)
10.5
14.0