Operation Checks
Check ignition, pilot stability, burner
fl
ames, and the full range of the thermostat using the rotary switch inside the
appliance and the remote control hand unit. See
Lighting Instructions
further on in this manual for full details.
Aeration adjustment
As described on page 30, burner aeration is adjustable. For the vast majority of installations, no adjustment will be
necessary. However, in a very few instances, performance may be improved by adjusting the aeration by sliding the
shutter. See
fi
gure 40 on page 30. Evaluate the aeration only after the unit has warmed up—approximately 15 minutes.
Increasing aeration will cause the
fl
ame to appear more transparent and blue making the ceramic fuel effects glow more.
Decreasing aeration will cause the
fl
ames to appear more yellow or orange making the fuel effects glow less.
Too little aeration may result in black carbon forming and dropping into the fi rebox.
Figure 50