INSTALLER’S GUIDE
Page 43
Figure 58. Removal of Electronic
Generator.
Figure 57. Ceramic support bracket
removal.
2.
Remove the battery.
3.
Remove the burner unit – see section
16.6.
4.
If lying the burner on its back,
unscrew and remove the two ceramic
support brackets from the top of the
burner unit. This will avoid damage to
the brackets and the work surface (see
figure 57).
5.
Remove the spark lead
6.
Unscrew the pipe clamp and two
support bracket screws. The generator
and its support bracket can now be
moved forward. Be careful not to
apply tension to the microswitch
leads.
7.
Remove the two fixing screws
that attach the generator unit to the
support bracket. The igniter
generator can now be removed.
(see figure 58)
8.
Remove the two leads to the
switch and remove the spark lead.
If necessary, mark them to ensure
that they are replaced on to the
correct terminals.
9.
Replace the generator
10.
Refit in the reverse order.
16.9
To Remove the
Thermocouple Interrupter Block
See figure 59.
1.
Remove the bottom front and
fire front castings and the front
surround - See section 16.3.
2.
Detach the thermocouple from
the interrupter block by
unscrewing the thermocouple nut.
3.
Detach the two microswitch
leads from the interrupter block.