INSTALLER’S GUIDE
Page 19
Figure 13. Fireback Spacers
Figure 12. “U” Seals
Figure 11. Burner Attachment Points
7 P R E P A R I N G A P P L I A N C E F O R
I N S T A L L A T I O N
IMPORTANT
Before continuing with the
installation of this gas fire the
aeration setting on the burner must
be checked. This has been factory
set. See section 16 (Servicing and
parts replacement).
4.
Detach the burner unit from the
hotbox by removing two screws - See
figure 11. Lift the burner unit clear.
5.
Fit the two “U” section seals to the
bottom edges of the hotbox side flanges. See
figure 12.
6.
For concealed connection only: There are
two removable circular panels at the rear of the
hotbox. Decide which one of these is to be used
for rear entry. Using a suitable tool apply
pressure to the centre of the removable
circular panel. There is a grommet in the
installation kit supplied with the fire. Fit this
into the hole. Pierce the grommet to allow the
pipe to pass through it. The grommet should
envelop the pipe. If the hole is larger than the
pipe, seal it with tape.
Do not pierce the
grommet unless the supply pipe is to pass
through it
.
7.
The appliance is supplied with two
fireback spacers.
Do not fit the fireback
spacers if the fire is to be installed into a
precast or clay flue block system as in
section 2.2.2
.These should extend backwards
to ensure sufficient clearance from the back
of the fireplace. Remove the label and
retaining screws from the rear sides of the
hotbox. Position the fireback spacer as shown