INSTALLER’S GUIDE
Page 7
the Environment for
Northern Ireland.
In the republic of Ireland
the installation must also
conform to the relevant
parts of:
a)
The current edition of
IS 813
b)
All relevant national
and local rules in force.
2.2
In the United
Kingdom, as supplied, the
appliance can be installed in
the following situations: -
2.2.1
To a fireplace
complete with surround and
hearth as shown in figure 1
and complying with
BS1251 after removal of
the fireback and sufficient
material behind the fireback
for a debris catchment space. The required fireplace, hearth, debris catchment area and
clearance dimensions are shown in figure 1.
2.2.1.1 ‘Hole-in-the-wall’ Installations
•
It is recommended that a hearth should be installed as in figure 1.
•
Icon firefront
If when using the Icon firefront a Hearth is not fitted, the fire must be installed so
that the distance from the base of the fireplace opening in the wall to the finished
floor level is at least 85mm.
•
Adorn and Visage firefront
If when using the Adorn and Visage firefronts a reduced depth Hearth is fitted, the
fire must be installed so that the distance from the base of the fireplace opening in
the wall to the finished floor level is at least 85mm. It is recommended that the
reduced hearth has a depth from the fixing plane of the fire of 100mm minimum.
This is necessary to support the lower front casting.
2.2.2
To a fireplace incorporating a metal flue box complying with the constructional
requirements of the current edition of BS715. The dimensions of the flue box must
conform to those shown in figure 2.
Figure 2. Metal Flue box dimensions