background image

Owner’s Information

Replacing Batteries

Low battery signal: see page 15.
BEFORE changing the batteries, disconnect the 
battery box from the receiver

.

The appliance uses four 1.5 V AA alkaline batteries 
for its battery box and one 9 V alkaline battery for its 
handset. Batteries should last one to two seasons, 
depending on usage. Removing the batteries in the off-
season will extend the battery life. Should the batteries 
loose power, the control may be operated by manually 
turning the control knob at the valve or by turning off 
the valve at the switch.

To replace the batteries in the battery box

1.  The battery box is located to the left of 

the 

fi

 rebox behind the left access door. 

Remove the left access door. Grab 
the battery box and pull it out from its 
location.

2.  Disconnect the battery box.

3.  Remove the box cover (1 

screw).

4.  Replace the 4 AA batteries.
5.  Replace the cover and screw in place.
6.  Reconnect the battery box.
7.  Put the battery box back in its position.
8.  Reinstall the left access door.

Locating Lighting, Operation and Rating 
Information Plate

The Lighting, Operation and Rating information plate is 
located at the right of the 

fi

 rebox. To access the plate, 

remove the right hand side door, grab the plate and 
take it out to read it. There is important information on 
both sides of the plate.

Servicing Your Fireplace

If any attention is required for your appliance, contact 
your supplier quoting the model number. It will be helpful 
if the appliance’s serial number can also be quoted. This 
number is on the rating plate, which is located at the 
right of the 

fi

 rebox. The replacement parts are shown 

at the end of this manual. Please always quote the part 
number and description when requesting spare parts.

Fireplace Control Devices

There are three ways to control your 

fi

 replace.

1.  Thermostatic Remote Control;
2.  Wall Switch (optional);
3.  Manual On/Off Switch.

The manual On/Off switch must be ON for the 

fi

 replace 

to function. It can be used to shut off the 

fi

 replace in 

case of emergency—see next sub-section.
The Thermostatic Remote Control can be programmed 
to function automatically—see pages 10–15.
The Wall Switch (optional) can be used to turn on, off 
and to increase or decrease the 

fl

 ame height—see 

1265WSK—Wall Switch Kit.

NOTE:

 The remote control in the AUTO mode will 

override the wall switch.

WARNING

DO NOT ATTEMPT TO TOUCH THE DATA PLATE 
WHILE THE FIREPLACE IS STILL HOT! 

Let the 

fi

 replace cool 

fi

 rst before touching it.

Wall Switch 

(optional)

Manual On/

Off Switch

Thermostatic Remote 

Control

CAUTION

DO NOT USE

 a screwdriver or other metallic object to 

remove the batteries from the receiver or the handset! 
This could cause a short circuit to the receiver.

WARNING

DO NOT ATTEMPT TO CHANGE THE BATTER-
IES WHILE THE FIREPLACE IS STILL HOT! 

Let 

the 

fi

 replace cool 

fi

 rst before touching it.

Battery 

box

8

OWNER’S 
INFORMATION

WARNING

!

WARNING

!

Summary of Contents for 780JP (LPG)

Page 1: ...ible en fran ais sur demande This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used...

Page 2: ...and Your Fireplace 4 Owner s Information 5 Operating Your Fireplace for the First Time 5 Cleaning Your Fireplace 6 Checking Pilot and Burner Flames 7 Using Handset Wall Holder 7 Replacing Batteries 8...

Page 3: ...BE PLACED on or near the appliance This unit MUST be used with a vent system as described in this installation manual NO OTHER vent system or components MAY BE USED This gas fireplace and vent assemb...

Page 4: ...e A physical barrier is strongly recommended if there are young children or at risk individuals in the house Install an approved after market safety gate to keep toddlers young children and other at r...

Page 5: ...ied dealer Each Valor fireplace is fully tested during the production process for your safety and comfort Your unit has been professionally installed by Dealer Name ________________________________ Ph...

Page 6: ...owever guarantee the results of these products BRASSO POLISH PLUS by KELKEM COOK TOP CLEAN CREME by ELCO WHITE OFF by RUTLAND TURTLE WAX Do not clean the glass while it is hot Always securely replace...

Page 7: ...the type of installation and climatic conditions Rocks Correct Flame Picture Pilot Flame can be seen between twig and rocks The appliance area must always be kept clear and free from combustible mate...

Page 8: ...e If any attention is required for your appliance contact your supplier quoting the model number It will be helpful if the appliance s serial number can also be quoted This number is on the rating pla...

Page 9: ...Ensure Your Fireplace Cannot Be Turned ON Inadvertently You can use one of the two following methods to ensure that your fireplace will not turn on when you don t want it on First ensure your firepla...

Page 10: ...ontrol system for the first time the receiver and the handset must be synchronized See the section Remote Control Initial Set up on page 35 of this manual Set scrolls through modes and settings OFF re...

Page 11: ...l flash after either Installing the battery or Simultaneously pressing the large flame and small flame buttons Press large flame button to set the hour Press small flame button to set the minute Press...

Page 12: ...the set temperature every 30 seconds NOTE 8 seconds after the fan has been set the handset will automatically go into temperature control mode The fan starts 4 minutes after the gas opens from OFF or...

Page 13: ...pm in each 24 hour cycle The Programs P1 and P2 must be set in the following order during a 24 hour cycle and The icon indicates the beginning of the period ON and the icon indicates the end of the p...

Page 14: ...eiver and the handset for a period of 6 hours the appliance goes into pilot mode No change in flame height If there is no change in flame height for a period of 6 hours the appliance goes into pilot m...

Page 15: ...to Propane Gas 780NGK Conversion Kit to Natural Gas Hearth Gate Hearth gates such as Cardinal s VersaGates are available at retail stores carrying safety products for children Information accurate at...

Page 16: ...ll gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 3 AUTOMA7 1 7 21 J RFDWH WKH SLORW J LQVLGH RI UHER DW HIW DQG VLGH 21 2 VZLWFK LQ 21 SRVL...

Page 17: ...ANSI NFPA 70 or the Canadian Electrical Code CSA C22 1 High Altitude Installations Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4 500 feet 1 370 m ab...

Page 18: ...imney Existing hearth must be non combustible as required for existing solid fuel burning fireplaces Trim sold separately WARNING HOT HEARTH FLOOR The hearth or floor in front of the fireplace may bec...

Page 19: ...el is combustible see following section for allowable clearances A hearth that is at a height within 4 102 mm of the bottom of the heater MUST be non combustible all trims except 799 Edgemont Door wit...

Page 20: ...de of the mantel to finished hearth or surface that the unit is sitting on Finishing Materials Combustible materials Material such as wood compressed paper plant fibers plastics or any material capabl...

Page 21: ...w hits the outside vent terminal from any direction Check local codes for allowable vertical vent termination Venting Table Maximum vertical height 40 ft measured to bottom of termination Minimum vert...

Page 22: ...ace cavity Generally no modifications are allowed to the existing fireplace that will compromise the integrity of the existing fireplace Components that are bolted or screwed on such as dampers or baf...

Page 23: ...1 5 inch 38 mm or less through the lower sides or bottom of the firebox The access hole must be plugged with non combustible insulation after the gas supply line has been installed See Dimensions sec...

Page 24: ...before the appliance is fitted into the cavity Refer to instructions provided with the 795CFKV2 to install the fan Remove Window The window is held in place by a spring loaded lever on each side 1 To...

Page 25: ...ack of the firebox 3 Apply RTV sealant to the collars on the vent slider and fit the two liners ensuring that the exhaust liner is connected to the identified EXHAUST vent collar Secure with 4 tapping...

Page 26: ...valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi 3 5 kPa Failure to either disconnect or isolate the appliance during pressure testing...

Page 27: ...es where local codes do not permit the flex connector to be used inside the appliance case reconnect the flex connector outside of the appliance case A cut out is provided in the appliance case for th...

Page 28: ...st the back of the firebox on the ledge at bottom 5 Rotate the anchor up and out of the way and slide the left hand side panel against the firebox side Rotate the anchor back down to hold the panel 6...

Page 29: ...iron grate in the slots in front of the burner 1 Center the rear log in the firebox Bring the log forward to rest against the sheet metal tabs behind the burner Install Ceramic Logs Unpack the cerami...

Page 30: ...end rests on the glass and should be rotated forward against the cast grate allowing flames to come up behind the left log 4 Place the right front log with its left end flat on the glass The notch in...

Page 31: ...logs Place its wider end on the front right log s peg and rest its narrow end in the notch on the rear log 7 Place the top left log s wider end on the peg of the front left log and rest its narrow en...

Page 32: ...se lies against the metal tabs behind the burner Metal tab 1 2 3 5 6 7 8 9 10 11 12 13 14 15 17 16 18 4 Install Ceramic Rocks Unpack the ceramic rocks very carefully to avoid damaging them Install the...

Page 33: ...amic platform Install these rocks positioning them so the arrow embossed underneath points to the front of the fireplace 14 11 9 7 17 18 13 6 8 10 8 Identify the rocks 7 9 11 and 14 These rocks have o...

Page 34: ...me as indicated below Window frame Bottom railing Burner rail Pilot These rocks overhang slightly above the burner but do not touch the black base IMPORTANT The rocks of the top row 14 11 9 and 7 over...

Page 35: ...y box upside on the left of the firebox Battery box connection Reset button Battery box Remove cover Connect battery box to wire 5 With a sharp object press and hold the receiver s reset button until...

Page 36: ...rmined only by operating the appliance with the ceramic logs and window installed Increasing aeration open will cause the flames to appear more transparent and blue showing more ceramic effects glow D...

Page 37: ...wall mounted holder This holder is not required in all installations but is provided as an optional feature for those customers who wish to mount the remote handset to the wall To install the holder t...

Page 38: ...Red Yellow Wiring Diagram Remote Battery Box Optional 795CFKV2 Fan Control Module 4 AA Batteries GV60 MAX Wiring Diagram Optional Wall Switch Kit 1265WSK Connector 38 QUALIFIED INSTALLER...

Page 39: ...ial Adapter 46DVA GK TM 4CTA 4DCAT33 Aluminum Flexible Liner 3 or 4 diameter NOTE 2 ply liner approved to CAN ULC S635 suitable for venting gas appliances As manufactured by Z Flex Flexmaster and othe...

Page 40: ...other household equipment or appliances iii Damage due to chemicals dampness condensation or sulphur in the fuel supply lines which exceeds industry standards i This warranty does not cover glass log...

Page 41: ...02698 32 Thermocouple pilot sealing plate 4002700 33 Thermocurrent interruptor 4001037 34a GV60 Valve assembly NG 4003098 34b GV60 Valve assembly LPG 4003111 Code Description Part Number 35 34 flex pi...

Page 42: ...7 b Enamel black 4004269EB c Ceramic fluted black 4004268 d Valor red brick 4004266 84 Left side panel a Ledgestone 4002365 b Enamel black 4002371EB c Ceramic fluted black 4002377 d Valor red brick 40...

Page 43: ...4 40 41 42 43 44 45 46 47 48 49 50 51 52 54 53 55 56 57 79 80 81 82 83 84 85 86 87 15 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 41a NG LPG 16 23a 24 25 26 27 32 33 34a 34b 35 38 3...

Page 44: ......

Page 45: ...tion provided will be used for customer records only Online Warranty registration at www valorfireplaces com Cut out page fill information and mail to Miles Industries Ltd Fireplace Information Model...

Page 46: ...hut Thank you for choosing a Valor Product Postage needed Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC V7H 3B1 Canada Fold here Online Warranty registration at www valorfireplace...

Reviews: