background image

Spare Parts

Code

Description

Part 

Number

1

Exhaust slide assembly

4002287

2

Exhaust slide gasket

4000176

3

Restrictor enclosure

4002330

4

Metal strip

4002329

5

Restrictor assembly

4002333

6

Coil spring

4002605

7

Rod support

4002331

8

Cover

4002289

9

Access panel gasket

4002664

10

Access plate

4002510

11

Shrouds (2)

4002446

12a

Log support NG

4002427BY

12b

Log support LPG

4003317S

13

Front brick support

4002428BY

14

Window frame assembly (inc glass)

4004463S

15

Module assembly NG

4002334S

Module assembly LPG

4002335S

16

Pilot assembly NG

4001690

Pilot assembly LPG

4001691

17

Thermocouple

4000061

18

Pilot injector #51 NG

4000735

Pilot injector #30 LPG

4000736

19

Pilot tube

4000732

20

Pilot hood 2 

fl

 ame

4000730

21

Extended nut

4001855

22

Electrode

4001856

23

Insulation sleeve

4002244

23a

Pilot shield

4003890BY

24

Burner assembly NG

4001665

Burner assembly LPG

4001666

25

Injector elbow #850 NG

9730010

Injector elbow #300 LPG

9730035

25a

Valve to injector pipe assembly

4002306

26

Burner support

4001850

27

Top gasket

4002403

28

Side gasket

4002404

29

Bottom gasket

4002405

30

Single pipe sealing plate

4002698

32

Thermocouple/pilot sealing plate

4002700

33

Thermocurrent interruptor

4001037

34a

GV60 Valve assembly NG

4003098

34b

GV60 Valve assembly LPG

4003111

Code

Description

Part 

Number

35

34” 

fl

 ex pipe with shut-off valve

4002475

36

Air shutter slider NG

4002345

37

Air shutter cover NG

4002346

38

Flashback shield LPG

3000371

39

Air shutter slider LPG

320B293

40

Auxiliary battery holder

4002249

41

Ignition cable

4001039

41a

Ignition cable sleeve

4002244

42

Switch with cable

4001036

43

Cable interrupter

4001035

44

Receiver G6R-R3AU (CP)

4002422

45

Handset G6R H3TV4-ZV1 (BJ)

4002251

46

Wiring harness

4001187

47

Handset wall holder

9000008

48

Log set complete

4002495

49

Left log

4002497

50

Rear log

4002496

51

Right top log

4002499

52

Left top log

4002498

53

Right front log

4002500

54

Left front log

4002501

55

Glass panel

4002423

56

Cast grate assembly

4001403AH

57

Location bracket

4002421

58

Centre piece

4002629

59

Rock no. 1

4002644

60

Rock no. 2

4002645

61

Rock no. 3

4002646

62

Rock no. 4

4002647

63

Rock no. 5

4002648

64

Rock no. 6

4002649

65

Rock no. 7

4002650

66

Rock no. 8

4002651

67

Rock no. 9

4002652

68

Rock no. 10

4002653

69

Rock no. 11

4002654

70

Rock no. 12

4002655

71

Rock no. 13

4002656

72

Rock no. 14

4002657

73

Rock no. 15

4002658

74

Rock no. 16

4002659

75

Rock no. 17

4002660

41

OWNER’S 
INFORMATION

Summary of Contents for 780JP (LPG)

Page 1: ...ible en fran ais sur demande This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used...

Page 2: ...and Your Fireplace 4 Owner s Information 5 Operating Your Fireplace for the First Time 5 Cleaning Your Fireplace 6 Checking Pilot and Burner Flames 7 Using Handset Wall Holder 7 Replacing Batteries 8...

Page 3: ...BE PLACED on or near the appliance This unit MUST be used with a vent system as described in this installation manual NO OTHER vent system or components MAY BE USED This gas fireplace and vent assemb...

Page 4: ...e A physical barrier is strongly recommended if there are young children or at risk individuals in the house Install an approved after market safety gate to keep toddlers young children and other at r...

Page 5: ...ied dealer Each Valor fireplace is fully tested during the production process for your safety and comfort Your unit has been professionally installed by Dealer Name ________________________________ Ph...

Page 6: ...owever guarantee the results of these products BRASSO POLISH PLUS by KELKEM COOK TOP CLEAN CREME by ELCO WHITE OFF by RUTLAND TURTLE WAX Do not clean the glass while it is hot Always securely replace...

Page 7: ...the type of installation and climatic conditions Rocks Correct Flame Picture Pilot Flame can be seen between twig and rocks The appliance area must always be kept clear and free from combustible mate...

Page 8: ...e If any attention is required for your appliance contact your supplier quoting the model number It will be helpful if the appliance s serial number can also be quoted This number is on the rating pla...

Page 9: ...Ensure Your Fireplace Cannot Be Turned ON Inadvertently You can use one of the two following methods to ensure that your fireplace will not turn on when you don t want it on First ensure your firepla...

Page 10: ...ontrol system for the first time the receiver and the handset must be synchronized See the section Remote Control Initial Set up on page 35 of this manual Set scrolls through modes and settings OFF re...

Page 11: ...l flash after either Installing the battery or Simultaneously pressing the large flame and small flame buttons Press large flame button to set the hour Press small flame button to set the minute Press...

Page 12: ...the set temperature every 30 seconds NOTE 8 seconds after the fan has been set the handset will automatically go into temperature control mode The fan starts 4 minutes after the gas opens from OFF or...

Page 13: ...pm in each 24 hour cycle The Programs P1 and P2 must be set in the following order during a 24 hour cycle and The icon indicates the beginning of the period ON and the icon indicates the end of the p...

Page 14: ...eiver and the handset for a period of 6 hours the appliance goes into pilot mode No change in flame height If there is no change in flame height for a period of 6 hours the appliance goes into pilot m...

Page 15: ...to Propane Gas 780NGK Conversion Kit to Natural Gas Hearth Gate Hearth gates such as Cardinal s VersaGates are available at retail stores carrying safety products for children Information accurate at...

Page 16: ...ll gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 3 AUTOMA7 1 7 21 J RFDWH WKH SLORW J LQVLGH RI UHER DW HIW DQG VLGH 21 2 VZLWFK LQ 21 SRVL...

Page 17: ...ANSI NFPA 70 or the Canadian Electrical Code CSA C22 1 High Altitude Installations Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4 500 feet 1 370 m ab...

Page 18: ...imney Existing hearth must be non combustible as required for existing solid fuel burning fireplaces Trim sold separately WARNING HOT HEARTH FLOOR The hearth or floor in front of the fireplace may bec...

Page 19: ...el is combustible see following section for allowable clearances A hearth that is at a height within 4 102 mm of the bottom of the heater MUST be non combustible all trims except 799 Edgemont Door wit...

Page 20: ...de of the mantel to finished hearth or surface that the unit is sitting on Finishing Materials Combustible materials Material such as wood compressed paper plant fibers plastics or any material capabl...

Page 21: ...w hits the outside vent terminal from any direction Check local codes for allowable vertical vent termination Venting Table Maximum vertical height 40 ft measured to bottom of termination Minimum vert...

Page 22: ...ace cavity Generally no modifications are allowed to the existing fireplace that will compromise the integrity of the existing fireplace Components that are bolted or screwed on such as dampers or baf...

Page 23: ...1 5 inch 38 mm or less through the lower sides or bottom of the firebox The access hole must be plugged with non combustible insulation after the gas supply line has been installed See Dimensions sec...

Page 24: ...before the appliance is fitted into the cavity Refer to instructions provided with the 795CFKV2 to install the fan Remove Window The window is held in place by a spring loaded lever on each side 1 To...

Page 25: ...ack of the firebox 3 Apply RTV sealant to the collars on the vent slider and fit the two liners ensuring that the exhaust liner is connected to the identified EXHAUST vent collar Secure with 4 tapping...

Page 26: ...valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi 3 5 kPa Failure to either disconnect or isolate the appliance during pressure testing...

Page 27: ...es where local codes do not permit the flex connector to be used inside the appliance case reconnect the flex connector outside of the appliance case A cut out is provided in the appliance case for th...

Page 28: ...st the back of the firebox on the ledge at bottom 5 Rotate the anchor up and out of the way and slide the left hand side panel against the firebox side Rotate the anchor back down to hold the panel 6...

Page 29: ...iron grate in the slots in front of the burner 1 Center the rear log in the firebox Bring the log forward to rest against the sheet metal tabs behind the burner Install Ceramic Logs Unpack the cerami...

Page 30: ...end rests on the glass and should be rotated forward against the cast grate allowing flames to come up behind the left log 4 Place the right front log with its left end flat on the glass The notch in...

Page 31: ...logs Place its wider end on the front right log s peg and rest its narrow end in the notch on the rear log 7 Place the top left log s wider end on the peg of the front left log and rest its narrow en...

Page 32: ...se lies against the metal tabs behind the burner Metal tab 1 2 3 5 6 7 8 9 10 11 12 13 14 15 17 16 18 4 Install Ceramic Rocks Unpack the ceramic rocks very carefully to avoid damaging them Install the...

Page 33: ...amic platform Install these rocks positioning them so the arrow embossed underneath points to the front of the fireplace 14 11 9 7 17 18 13 6 8 10 8 Identify the rocks 7 9 11 and 14 These rocks have o...

Page 34: ...me as indicated below Window frame Bottom railing Burner rail Pilot These rocks overhang slightly above the burner but do not touch the black base IMPORTANT The rocks of the top row 14 11 9 and 7 over...

Page 35: ...y box upside on the left of the firebox Battery box connection Reset button Battery box Remove cover Connect battery box to wire 5 With a sharp object press and hold the receiver s reset button until...

Page 36: ...rmined only by operating the appliance with the ceramic logs and window installed Increasing aeration open will cause the flames to appear more transparent and blue showing more ceramic effects glow D...

Page 37: ...wall mounted holder This holder is not required in all installations but is provided as an optional feature for those customers who wish to mount the remote handset to the wall To install the holder t...

Page 38: ...Red Yellow Wiring Diagram Remote Battery Box Optional 795CFKV2 Fan Control Module 4 AA Batteries GV60 MAX Wiring Diagram Optional Wall Switch Kit 1265WSK Connector 38 QUALIFIED INSTALLER...

Page 39: ...ial Adapter 46DVA GK TM 4CTA 4DCAT33 Aluminum Flexible Liner 3 or 4 diameter NOTE 2 ply liner approved to CAN ULC S635 suitable for venting gas appliances As manufactured by Z Flex Flexmaster and othe...

Page 40: ...other household equipment or appliances iii Damage due to chemicals dampness condensation or sulphur in the fuel supply lines which exceeds industry standards i This warranty does not cover glass log...

Page 41: ...02698 32 Thermocouple pilot sealing plate 4002700 33 Thermocurrent interruptor 4001037 34a GV60 Valve assembly NG 4003098 34b GV60 Valve assembly LPG 4003111 Code Description Part Number 35 34 flex pi...

Page 42: ...7 b Enamel black 4004269EB c Ceramic fluted black 4004268 d Valor red brick 4004266 84 Left side panel a Ledgestone 4002365 b Enamel black 4002371EB c Ceramic fluted black 4002377 d Valor red brick 40...

Page 43: ...4 40 41 42 43 44 45 46 47 48 49 50 51 52 54 53 55 56 57 79 80 81 82 83 84 85 86 87 15 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 41a NG LPG 16 23a 24 25 26 27 32 33 34a 34b 35 38 3...

Page 44: ......

Page 45: ...tion provided will be used for customer records only Online Warranty registration at www valorfireplaces com Cut out page fill information and mail to Miles Industries Ltd Fireplace Information Model...

Page 46: ...hut Thank you for choosing a Valor Product Postage needed Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC V7H 3B1 Canada Fold here Online Warranty registration at www valorfireplace...

Reviews: