10.8 Using the remote control handset.
1.
Keep the pilot burner at the "main burner on" position. Check the full range of main
burner heat settings using the remote control handset. In order to vary the flame
effect between High and Low positions, press, and keep depressed, either the High
button, or the Low button as appropriate (See figure 25).
The handset operates on ultrasonic principles, and as such it is not necessary to
point it directly at the fire.
2.
Use the handset to switch to
the pilot only setting by
depressing the Low button until
only the pilot flame remains
alight.
3.
In order to disable the
handset, but still leave the pilot
alight, turn the pilot burner
control knob to the ignition
position (2 in figure 24).
4.
Turn the fire off by rotating
the pilot burner control knob to the OFF position (1 in figure 24).
10.9 Inlet pressure check.
The appliance is pre-set to give the correct heat input at the inlet pressure shown in
section 2 of this guide. No adjustment is necessary.
1.
Check the inlet pressure by fitting a pressure gauge at the test point. The test point
is on the inlet ‘T’ connector (See figure 26). Check
the pressure with the appliance alight and set at
maximum output.
2.
After checking, turn off the appliance. Remove
the pressure gauge and replace the test point
sealing screw.
3.
Relight the appliance. Turn to the maximum
output position and test around the sealing screw
for gas soundness with a suitable leak detection
fluid.
Page 29
©
Baxi Heating U.K. Limited 2009.
Figure 26. Pressure test point
Figure 25. Remote control handset.
INSTALLER GUIDE