holes should be drilled within the range of positions shown in figure 17 using a
suitably sized masonry drill. The holes should be
equidistant each side of the centre line of the
fireplace to ensure that the appliance finishes
centrally in the opening when tension is applied to
the cables.
3.
Insert a fibre / wooden wall plug into each hole.
Use the fibre / wooden wall plugs supplied with this
appliance -
Never use plastic plugs instead of
the fibre / wooden wall plugs supplied
.
Screw
the eyebolts into the plugs. Make sure that the bolts
are secure.
4.
Place the hotbox unit close to the fireplace but
allow sufficient access into the fireplace opening so
that the cables can be threaded through the eyebolts
and returned through the back of the hotbox. If a
concealed connection is being used, insert the hotbox
into the fireplace feeding the supply pipe through the
pierced hole in the rear grommet.
5.
The hotbox has two holes at each side of the
spillage plate. Insert one end of each cable (one cable
each side) from the back through the lower of the two
holes and return the end through the upper of the
holes (See figure 18). Give the cables a pull so that
they grip against the hotbox flanges.
6.
Thread the cables through the eyebolts. Return the
cables through the holes near the bottom of the
hotbox back panel (See figure 19)
(For precast or
clay block flue systems return the cables through
the slotted holes in the side of the hotbox)
.
7.
Place the hotbox fully back into the fireplace
opening so that it is sealed against the fireplace front
surround.
8.
Drill a hole into the fireplace floor through each of
the two holes in the base of the hotbox using a
suitably sized masonry drill (See figure 20).
9.
Insert a fibre / wooden wall plug into each hole.
Use the fibre / wooden wall plugs supplied with this
appliance -
Never use plastic plugs instead of the
fibre / wooden wall plugs supplied
.
Fit a wood
screw in each plug and tighten.
Always screw the base into position before applying tension to the cables. This
will ensure a tight seal between the top of the hotbox and wall.
10.
Fit a cable retainer over the bottom end of each cable.
Page 25
©
Baxi Heating U.K. Limited 2009.
Figure 20. Floor fixing
Figure 19. Cable route.
Figure 18. Upper cable retention
INSTALLER GUIDE