Troubleshooting
Valentine TF3 fryers are fitted with a safety thermostat. These safety thermostats are placed in
the heater housing at the back of the fryer. The red reset button [6] is apparent underneath the
housing.
It is triggered when the oil temperature exceeds 230°C or in case there is no oil in the fryer
To reset the thermostat:
Stop the fryer
(thermostat switch [1] to Pos. "0")
and unplug the appliance
Allow the fryer to cool down
(to speed this process up lift the heating element and
place it on the lid). As long as the thermostat bulb attached to the heater is hot, you cannot
reset the safety thermostat
Press down firmly on the red button
(until you hear the « click » )
Problem
Probable cause
Action
No control lamp is lit, the fryer is
not heating.
No power
Housing not properly in place
Carefully check the fuses, plug
and socket
Check that the housing is in the
correct position
The white power lamp is lit, but
not the yellow for heating
Safety thermostat has been
activated
Reset it (see above)
The control lamp are lit but the
fryer does not heat up
Heating element or the thermo-
stat is defective
Call the after-sales service
Other malfunctioning
Call the after-sales service team