9
Installation
NOTE: Measure burner operating pressure at
manifold test point with both burners
operating at ‘Full’ setting.
8.
Verify operating pressure remains correct.
Commissioning
1.
Before leaving the new installation;
a. Check the following functions in accordance with operating instructions specified in ‘Operation’
section of this manual.
Light the Pilot Burner.
Light the Main Burners.
Check the Low Fire burner operation.
Check the High Fire burner operation.
b. Ensure operator has been instructed in areas of correct lighting, operation, and shutdown
procedure for appliance.
2.
This manual must be kept by owner for future reference, and a record of
Date of Purchase, Date
of Installation and Serial Number of Appliance recorded and kept with this manual. (These
details can be found on Rating Plate attached to R/H inner side panel (refer to para-
graph ‘Gas Connection’ earlier in this section).
NOTE: If for some reason it is not possible to get appliance to operate correctly, shut ‘Off’ gas
supply and contact supplier of this appliance.
Pressure Test Point
Low Fire Adjustment