![Valdorf GT8600G Installation And Operation Manual Download Page 6](http://html1.mh-extra.com/html/valdorf/gt8600g/gt8600g_installation-and-operation-manual_3190400006.webp)
4
Specifications
- UK Only:
Category:
II
2H3P
(20, 30 / 37).
Flue Type:
A
1.
NOTE:
* - Measure burner operating pressure at manifold test point with both burners operating at full
setting. Operating pressure is ex-factory set, through appliance regulator and is not to be
adjusted, apart from when converting between gases, if required. (Refer to ‘Gas Conversion’ sec-
tion for details).
- All Other Markets:
(*) NOTE:
Measure Burner operating pressure at manifold test point with two burners operating at
'High Flame' setting.
NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted,
unless when converting between gases, if required.
TOWN GAS Only - Adjust burner operating pressure using adjustable gas regulator
supplied.
Refer to ‘Gas Conversion and Specifications' section in this manual for further details.
Gas Connection
Gas supply connection point is located 130mm from right hand side of appliance, 32mm from rear,
654mm from floor and is entered from beneath appliance. An optional underside connection is
available.
Natural Gas (G20)
Propane (G31)
Heat Input (nett)
Nominal
11.0 kW
11.0 kW
Reduced
6.0 kW
5.6 kW
Gas Rate (nett)
Nominal
1.16 m
3
/hr 0.85
kg/hr
Reduced
0.63 m
3
/hr 0.44
kg/hr
Supply Pressure
20 mbar
37 mbar
Burner Operating Pressure
10 mbar (*)
26 mbar (*)
Gas Connection
1
/
2
” BSP Male
Pilot
170W 150W
Pilot
0.02 m
3
/hr 0.01
kg/hr
Natural Gas
Town Gas (**)
Input Rating (N.H.G.C.)
42MJ/hr 42MJ/hr
Supply Pressure
1.13 - 3.40kPa
0.75 - 1.50kPa
Burner Operating Pressure (*)
1.0kPa (*)
0.63kPa (*)
Gas Connection
1
/
2
” BSP Male
LP Gas (Propane)
Butane
Input Rating (N.H.G.C.)
42MJ/hr 42MJ/hr
Supply Pressure
2.75 - 4.50kPa
2.75 - 4.50kPa
Burner Operating Pressure (*)
2.5kPa (*)
2.5kPa (*)
Gas Connection
1
/
2
” BSP Male