![Valdorf GT8600G Installation And Operation Manual Download Page 19](http://html1.mh-extra.com/html/valdorf/gt8600g/gt8600g_installation-and-operation-manual_3190400019.webp)
17
Gas Conversion and Specifications
Gas Regulator
NAT Gas / LPG / Butane Only.
NOTE: The gas regulator supplied is convertible between Natural Gas and LP Gas, but it’s outlet
pressure is fixed ex-factory and is NOT to be adjusted.
- Town Gas Only.
1.
Remove slotted cap from regulator.
2.
Turn ‘On’ gas supply and appliance.
3.
Adjust pressure adjusting screw to achieve correct burner
operating pressure.
NOTE: Operating pressure to be measured at manifold test
point with both burners operating at 'High Flame'
setting.
4.
Turn ‘Off’ mains gas supply and bleed gas out of appliance gas lines.
5.
Turn ‘On’ gas supply and appliance.
6.
Verify operating pressure remains correct (Re-adjust regulator if required).
7.
Screw cap nut back onto regulator.
Gas Type Identification Label
On completion of gas conversion, replace gas type identification label located at:-
- Rear of appliance, above gas connection.
- Beside the rating plate.
Commissioning
Before leaving the installation;
1.
Check all gas connections for leakage using soapy water or other gas detecting equipment.
2.
Carry out a ‘Commissioning’ check of appliance as shown in Installation Section of this manual.
3.
Ensure any adjustments done to components that have adjustments / settings paint sealed are to be
re-sealed.
NOTE, Pin rotated
for Natural Gas
NOTE, Pin rotated
for LPG
Pressure Adjusting
Screw
Cap Nut
D
O
NOT
USE
A
NAKED
FLAME
TO
CHECK
FOR
GAS
LEAKAGES
.
Warning