Valcourt SRF40 Owner'S Manual Download Page 1

Printed in Canada

READ AND KEEP THIS MANUAL FOR REFERENCE

WARNING

46195U_A

OWNER’S 

MANUAL

ENGLISH

 FIRE OR EXPLOSION HAZARD 

•  Failure to follow safety warnings exactly could result in 

serious injury, death or property damage.
•  Do not store or use gasoline or other flammable vapors 

and liquids in the vicinity of this or any other appliance.

 WHAT TO DO IF YOU SMELL GAS 

•  Do not try to light any appliance.
•  Do not touch any electrical switch; do not use any phone 

in your building.
•  Leave the building immediately.
•  Immediately call your gas supplier from a neighbor’s 

phone. Follow the gas supplier’s instructions.
•  If you cannot reach your gas supplier, call the fire department.
•  Installation and service must be performed by a qualified 

installer, service agency or the gas supplier.

 WARNING 

•  If not installed, operated and maintained in accordance 

with the manufacturer’s instructions, this product could 

expose you to substances in fuel or from fuel combustion 

which can cause death or serious illness.
•  This appliance may be installed in an aftermarket, 

permanently located, manufactured home (USA only) or 

mobile home, where not prohibited by local codes.
•  This appliance is only for use with the type of gas 

indicated on the rating plate.
•  This appliance is not convertible for use with other 

gases, unless a certified kit is used.
•  Fuels used in gas, wood-burning or oil fired appliances, and 

the products of combustion of such fuels, contain chemicals 

known to the State of California to cause cancer, birth defects 

or other reproductive harm. For more information go to   

www.P65warnings.ca.gov/

2021-11-10

  

DANGER

HOT GLASS

 WILL CAUSE BURNS. 

DO NOT TOUCH

 GLASS UNTIL 

COOLED. 

NEVER

 ALLOW CHILDREN TO TOUCH GLASS. A barrier 

designed to reduce the risk of burns from the hot viewing glass is provided 
with this appliance and shall be installed for the protection of children and 
other at-risk individuals. NOTE : Barrier required, may be sold separately.

Safety tested

according to ANSI Z21.88-2017

and CSA 2.33-2017 standards

by an accredited laboratory.

MODEL

SRF40

(FG00002 & FG00020)

DIRECT VENT  

ZERO CLEARANCE 

GAS FIREPLACE HEATER

MULTIFUNCTION REMOTE (MF)

Summary of Contents for SRF40

Page 1: ...e death or serious illness This appliance may be installed in an aftermarket permanently located manufactured home USA only or mobile home where not prohibited by local codes This appliance is only fo...

Page 2: ...Dealer Installer Phone Number Serial Number...

Page 3: ...nstallation It is also highly recommended to inform your home insurance company Please read this entire manual before installing and using this fireplace If this fireplace is not installed properly co...

Page 4: ...Page 4 Owner s Manual SRF40 ENGLISH...

Page 5: ...hting Instructions 13 4 Operating Instructions 14 4 1 Noise coming from the fireplace 15 4 2 First operation 15 4 3 Controls 15 MAINTENANCE AND SERVICE 5 Service call 24 6 Invisimesh barrier and glass...

Page 6: ...Page 6 Owner s Manual SRF40 ENGLISH CERTIFICATION PLATE...

Page 7: ...becomes damaged the barrier shall be replaced with the manufacturer s barrier for this appliance 6 Clothing or other flammable material should not be placed on or near the appliance 7 Any safety scree...

Page 8: ...ich the appliance s connected to the venting system are located and other spaces of the building 4 Close fireplace dampers 5 Turn on clothes dryers and any appliance not connected to the venting syste...

Page 9: ...ow areas Stay out until firefighters declare them to be safe Use your neighbor s phone and call a trained Propane Gas service person and the fire department Even though you may not continue to smell g...

Page 10: ...rea where the conditions are such that you may not detect the odor if there has been a leak of Propane Gas Odor fade due to oxidation by rust or adsorption on walls of new cylinders and tanks is possi...

Page 11: ...ot avoided WILL RESULT IN DEATH or serious injury WARNING Indicates a hazardous situation which if not avoided COULD RESULT IN DEATH or serious injury CAUTION Indicates a hazardous situation which if...

Page 12: ...term qualified agency means any individual firm corporation or company which either in person or through a representative is engaged in and is responsible for a the installation or replacement of gas...

Page 13: ...t has been underwater Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been underwater LIGHTING INST...

Page 14: ...stay lit for many hours Turn off the fireplace if it is not going to be attended for any length of time Always place the transmitter where children can not reach it DO NOT USE a screwdriver or other...

Page 15: ...e the blower in the OFF position during this time It is normal for your gas fireplace to give off some odor the first time it is burned This is due to the curing of the paint and oil from the manufact...

Page 16: ...F40 ENGLISH 2 With a multifunction thermostatic Remote Transmitter ON OFF SMART Button Technical Data Remote Control Supply voltage 4 5 V three 1 5 V AAA batteries Ambient temp ratings 0 50 C 32 122 F...

Page 17: ...wall remote slide switch to the REMOTE position 4 Press and release the PRG button on the wall control with a paper clip and the IFC module will beep three times to indicate the IFC module is ready to...

Page 18: ...ature and a snowflake as show by the image on the right ON OFF REMOTE PRG To turn the system on make sure the wall remote is on mode REMOTE then press the ON OFF button on the transmitter The transmit...

Page 19: ...the down arrow button once will reduce the flame height by one step until the flame is turned off The up arrow button will increase the flame height each time it is pressed If the up arrow button is...

Page 20: ...t the room thermostat is ON and the set temperature is now displayed To adjust the set temperature press the up or down arrow buttons until the desired set temperature is displayed on the LCD screen o...

Page 21: ...nsity of the lights can be controlled by the proflame system The light has five levels of intensity plus off To activate this function use the MODE button see 4 3 Controls to index the light control i...

Page 22: ...at the same time To deactivate this function press the MODE and UP buttons at the same time OFF 4 3 14 Low Battery Power Detection The life span of the remote control batteries depends on various fac...

Page 23: ...entered automatically by the IFC board When the IFC board gets into lockout state 1 both the pilot and the main burner solenoids in the gas valve are de energized 2 a diagnostic code is sent through...

Page 24: ...al 4 Do not abuse or strike the glass CAUTION The Invisimesh barrier must be handled with care A slight deformation could impair its invisibility properties Avoid putting pressure on the mesh and make...

Page 25: ...around the latch before trying to disengage the clips Glass clips are tightly sprung If the latch tool slips off of the latch while pulling injury may occur 6 1 Glass cleaning Clean the glass before...

Page 26: ...ety device It must be replaced in case of any physical damage such as bent terminals missing parts stripped threads or evidence of exposure to excessive heat 7 1 Fireplace cleaning Cleaning Procedure...

Page 27: ...be susceptible to accidental contract burns Have your dealer install a physical barrier if there are at risk individuals in your home To restrict access to a fireplace or stove install an adjustable s...

Page 28: ...off in no more than 30 seconds BURNERS PILOT Vacuum and clean any foreign debris in the firebox that is not supposed to be there Inspect and ensure that the lighting of the main burner occurs within 4...

Page 29: ...nds 1 Remove the barrier and the glass door assemblies 5 16 8X 2X 2 Lift the light access cover up and out of the firebox 3 Remove the bulb s to be replaced 7 4 Blower replacement CAUTION Sharp Edges...

Page 30: ...END TAB INWARD HAND BEND TAB INWARD 4 Remove blowers brackets held in place by 6 screws each using a powerdriver and a 5 16 hexagonal socket 5 Replace blower onto blower bracket Bend tab as shown and...

Page 31: ...Gas Valve CAUTION Sharp Edges Use gloves and eye protection when servicing the fireplace controls Notice Always turn off gas and electrical supply to the fireplace before servicing the controls 1 Remo...

Page 32: ...ket secured with 3 screws to the top of the firebox and gently remove the top liner 5 16 3X 4 Remove the side liner panel located to the right If applicable loosen the 2 screws holding the right liner...

Page 33: ...ual SRF40 ENGLISH 6 Remove the screw holding the bottom of the gas valve housing Keep the scew Unscrew the burner gas intake tubes nuts 5 16 9 16 7 Slide out the gas valve housing 1 2 SPLIT FLOW SOLEN...

Page 34: ...rebox The 120V power cord is routed through the lower right side opening and plugged into the Junction Box receptacle DETAIL P 7 6 Maintenance Frequency Maintenance frequency must be determined indivi...

Page 35: ...orrosion of caps pipe and fittings It may be caused by having excessive lateral runs too many elbows and exterior portions of the system being exposed to cold weather 4 Inspect joints to verify that n...

Page 36: ...Pilot igniter sensor is dirty Clean pilot Pilot not grounded well Check ground connections Draft in firebox Vent restrictor not installed Pilot sensor has been bent Replace pilot Pilot will not ignite...

Page 37: ...mostat setting Move optional remote away from fireplace Set higher temperature on Optional remote thermostat Optional Remote control batteries failing Replace batteries in remote transmitter and recei...

Page 38: ...e wire harness 4 Replace the IFC board 1 Verify the electrical connections integrity and make sure they are in accordance with the relevant system wiring diagram If necessary replace the wire harness...

Page 39: ...ve the provided wiring harnesses from EV2 of gas valve red base and verify voltage at ignition between the EV1 terminal and the ground connection on the valve body 5 1 If the voltage is greater than 0...

Page 40: ...5 1 1 2 6 7 8 9 16 17 18 19 15 53 E DETAIL E 60 59 58 57 64 63 62 48 49 51 50 66 69 70 71 65 72 30 A F C D E B G H I J K 44 39 40 47 46 45 38 42 41 37 43 10 B DETAIL B 14 12 13 11 12 13 A DETAIL A 3 6...

Page 41: ...LY COMPLETE 1 5 PL71132 LATCH TOOL 1 6 49703 CONVERTIBLE PILOT ASSEMBLY 1 7 SE71145 BURNER BASE ASSEMBLY 1 8 49705 FRONT BURNER TUBE 1 9 49706 REAR BURNER TUBE 1 10 PL71161 BRICK LINER BRACKET 1 11 49...

Page 42: ...68 GASKET STRIP 8 1 4 X 1 2 X 1 4 2 55 21567 GASKET STRIP 10 3 4 X 1 2 X 1 4 2 56 SE71135 LIGHT HOUSING ASSEMBLY 2 57 44229 35W LIGHT BULB 2 58 21561 ACCENT LAMP GASKET w PSA 2 59 44230 ACCENT LAMP CE...

Page 43: ...BONE REAR LINER FOR SRF40 1 83 22346 HERRINGBONE RIGHT LINER FOR SRF40 1 84 AC04322 BLACK REFLECTIVE GLASS PANELS 1 85 PL71282 HORIZONTAL TRIM 1 86 PL71357 UPPER BRACKET 2 87 23104 LEFT GLASS PANEL AC...

Page 44: ...Black Finishing Trim3 AC04325 Herringbone Brick Panels6 AC04326 Large Black Finishing Trim7 AC04328 Black Reflective Glass Panels6 AC04322 Driftwood Logs Ember and Black Glowing Wool5 AC04347 Oxford...

Page 45: ...Page 45 Owner s Manual SRF40 ENGLISH...

Page 46: ...he defect The manufacturer may at its discretion fully discharge all obligations with respect to this warranty by refunding the wholesale price of any warranted but defective parts The manufacturer sh...

Page 47: ......

Page 48: ...com This document is available for free download on the manufacturer s website It is a copyrighted document Resale is strictly prohibited The manufacturer may update this document from time to time a...

Reviews: