TABLE 2 – LIST OF MANDATORY COMPONENTS
CHIMNEY
MANUFACTURER
MANDATORY COMPONENTS
TYPE/BRAND
Selkirk
Ventilated roof flashing
2" Solid Pack:
SuperVent 2100
(JM), Super Pro 2100
(ALT), Sentinel (CF)
ICC
Ventilated roof flashing
1" Solid Pack: Excel
2100
Cheminée Sécurité
Ventilated roof flashing
2" Solid Pack: S-
2100
Simpson Dura-Vent
Ventilated roof flashing
2" Solid Pack: Dura
Plus HTC
4.3
Chimney Installation Notes
1. If possible, install an interior chimney as it will provide better performance. In areas with
continuous temperatures below
18
C (0
F), the use of an exterior chimney increases the
likelihood of operating problems such as low draft, high rate of creosoting, and poor start-
up characteristics. Exterior chimneys are also prone to down-drafting and flow reversal.
Installations, which are located on lower floors in the house, such as in a basement, in
combination with outside chimney, are especially prone to flow reversal.
2. The FP7-LM ANTOINETTE is listed only with chimney systems described in table 1.
3. A chimney venting a fireplace shall not vent any other appliance.
4. The minimum chimney system height for a straight installation is 15 ft. (4.6 m) including
the height of the fireplace itself.
5. All chimney installations must include at least one support. Reducing the amount of
chimney weight on the fireplace will help avoid the noise created when the fireplace
expands. This can be achieved by having the chimney supported by the supports. The
maximum chimney length that should be supported by the fireplace is 9 ft. (2.75 m) for 2"
Solid Pack Chimney and 12 ft. (3.7 m) for 1" Solid Pack Chimney.
6. The chimney must extend at least 3 ft. (92 cm) above its point of contact with the roof and
at least 2 ft. (61 cm) higher than any wall, roof or building within 10 ft. (3.1 m) of it. See
Figure 30a and 30b
to determine the configuration that applies to your roof (flat or
sloped roof and the distance between the chimney and the highest point of the roof and/or
the nearest chimney).
7. Deviations should be avoided whenever possible, especially the most pronounced. Each
deviation adds some restriction to the chimney system and may lead to draft problems.
Summary of Contents for FP-7-LM ANTOINETTE
Page 16: ...16 Figure 13 Figure 14...
Page 17: ...17 Figure 15...
Page 18: ...18 Figure 16...
Page 19: ...19 Figure 17 Insulated chase construction...
Page 20: ...20 Figure 18 Spacers must be installed...
Page 22: ...22 Facing With the Narrow Overlap Figure 19...
Page 23: ...23 Facing With the Masonry Trim Figure 20...
Page 26: ...26 Figure 23...
Page 28: ...28 Figure 24 Figure 25...
Page 39: ...39 EXAMPLE OF TYPICAL CHIMNEY INSTALLATION Figure 33...
Page 41: ...41 Figure 34 Figure 35...