Task
Checked OK/Not OK
Remarks
Parameters are set.
See
3.6 Digital AFC (DAFC) (page 50)
.
Test Passed
For Customer
Date:
For Vaisala
Date:
A.19 MFC Functional Test and Tuning
(Optional)
Test Goal
Verify that the Manual Frequency Control (MFC) is functioning properly.
Skip this test if you are not using the RVP900 AFC.
Test Equipment
KVM connected
Test Procedure
1. Enter the TTY setups through
dspx
.
2. Type the
Ps
command (Plot burst spectrum and AFC).
3. Type the
=
command to enter the MFC (manual frequency control) mode.
Verify that the MFC mode is indicated by the
Manual
notation next to the AFC
%
output
indicator on the terminal.
4. Use the
U/u
and
D/d
commands and verify that these commands shift the measured IF
frequency (as displayed on the TTY) either up or down.
The
U
command should increase the frequency and the
D
command should decrease
the frequency. If the sense is reversed, go to the
Mb
command menu and change the
question
Burst frequency increases with increasing AFC voltage
.
RVP900 User Guide
M211322EN-J
358
Summary of Contents for RVP900
Page 1: ...M211322EN J User Guide RVP900 Digital Receiver and Signal Processor RVP900...
Page 22: ...RVP900 User Guide M211322EN J 20...
Page 88: ...RVP900 User Guide M211322EN J 86...
Page 170: ...RVP900 User Guide M211322EN J 168...
Page 236: ...RVP900 User Guide M211322EN J 234...
Page 390: ...RVP900 User Guide M211322EN J 388...
Page 434: ...Figure 68 ASR9 WSP with RVP7 Architecture RVP900 User Guide M211322EN J 432...
Page 456: ...Figure 82 J90 to J111 Wiring Diagrams RVP900 User Guide M211322EN J 454...
Page 457: ...Figure 83 J13 Wiring Diagram Appendix H TDWR Customizations 455...
Page 468: ...RVP900 User Guide M211322EN J 466...
Page 482: ...RVP900 User Guide M211322EN J 480...
Page 483: ......
Page 484: ...www vaisala com...