5.1.1 Installing Mounting Bracket on 60 ... 100 mm Mast
• 5
‑
mm Allen key
For optimum installation, the material of the tube or mast is a minimum of 3 mm
(0.12 in) thick and the outside diameter of the tube or mast is 60 … 100 mm
(2.36 ... 3.94 in).
For masts with a diameter of 60 ... 100 mm (2.36 ... 3.94 in), use the APPKP mounting kit. The
options are:
• APPKP60-SET1/2: Ø 60 mm (2.36 in) pole mast
• APPKP75-SET1/2: Ø 75 mm (2.95 in) pole mast
• APPKP86-SET1/2: Ø 86 mm (3.39 in) pole mast
• APPKP100-SET1/2: Ø 100 mm (3.94 in) pole mast
1. Attach the mounting bracket to the clamp and mount the assembly on the mast.
1
Mounting bracket
2
Clamp
3
Nut DIN985 M6 (2 pcs)
4
Washer DIN125 M6 (4 pcs)
5
Spring washer DIN127 M6 (2 pcs)
6
Hex screw DIN912 M6×16 (2 pcs)
7
Nut DIN929 M6 (2 pcs)
8
Spring washer DIN127 M6 (2 pcs)
9
Hex screw DIN912 M6×25 (2 pcs)
5.1.2 Installing Mounting Bracket on Sensor Support Arm or
35 ... 40 mm Mast
• 5
‑
mm Allen key
Chapter 5 – Installation