USER'S GUIDE____________________________________________________________________
120 _________________________________________________________________ M210762EN-D
ECHO
Use the
ECHO
[
x
] command to enable/disable echo of characters
received over the serial line.
Syntax:
ECHO
[
x
]
where
x
=
ON/OFF (default = OFF)
When using 2-wire connection, echo must be always disabled.
SMODE
Use the
SMODE
[
xxxx
] command to set the serial interface mode.
where
xxxx
=
STOP, RUN, POLL or SEND
In STOP mode:
measurements output only by command,
all commands can be used
In RUN mode:
outputting automatically, only command
S can be used to stop, see command
In POLL mode:
measurements output only with
command SEND. See command
on page 121.
In SEND mode:
no commands are needed, a message is
automatically outputted after power-up
When several transmitters are connected to the same line, each
transmitter must be issued an own address in the initial configuration,
and POLL mode must be used.
INTV
Use the
INTV
[
n xxx
] command to set the RUN mode output interval.
Syntax:
INTV
[
n xxx
]
where
n
=
1 - 255
xxx
=
S, MIN or H