More information
‣
Vaisala Rain Detector DRD11A (page 20)
‣
Wiring for AWS310-SITE with DMU703 and DRI701 (page 69)
4.4 Installing DRS511
Vaisala strongly recommends that only certified technicians install
embedded sensors.
CAUTION!
Install DRS511 on the wheel track 1 … 3 mm (0.04 … 0.12 in) below the road or runway
surface. This installation depth allows enough moisture to accumulate on top of the sensor
to determine salt concentration, but not to collect water excessively.
More information
‣
Necessary equipment for embedded sensor installation (page 35)
‣
Cable ducting for embedded sensors (page 37)
‣
Cutting slot for DRS511 installation (page 38)
‣
‣
Preparing DRS511 for installation (page 42)
‣
Installing DRS511 using cold filling material (page 43)
‣
Installing DRS511 using hot filling material (page 46)
4.4.1 Necessary equipment for embedded sensor installation
Follow the local regulations regarding the installation material and process. These
instructions describe a few alternatives.
The following tables list the tools and equipment usually needed for installing embedded
surface sensors. Depending on local regulations, you may also need other tools and
equipment.
Table 10 Equipment needed for embedded sensor installation
Equipment
Specifications
Diamond saw
Must be able to cut asphalt 80 … 90 mm (3.15 … 3.45 in) deep and preferably
12 … 30 mm (0.47 … 1.18 in) wide with a single pass, depending on the width of
the cable slot. For cable slot requirements, see
Chapter 4 – Installation
35
Summary of Contents for AWS310-SITE